CHAPTER 3
The Menu System
Cyberlight
®
2.0 User Manual
23
Performing Self Tests (SELF)
The following self tests are available:
Parameter
Self-Test Description
PAN
Moves through the entire pan range
TILT
Moves through the entire tilt range
SHUT
Tests Shutter strobe movement
CYAN
Moves the specific pair of color flags selected
MAGN
YELW
COLR
Static color wheel function
LT1
Rotating Gobo Wheel: wheel movement
LT1R
Rotating Gobo Wheel: rotating gobo movement
LT2
Static Gobo Wheel movement
IRIS
Tests Iris function
FX
Tests Effects wheel motion
ZOOM
Moves the Zoom lens through the range
FCUS
Moves through the Focus range
FRST
Tests Frost flags movement
To start a self test process:
1. Press and hold <Menu> until
AddR
appears on the LED display.
2. Scroll to the
TEST
menu. Press <Enter> to select.
3. Scroll to the
SELF
menu. Press <Enter> to select.
4. Scroll to the desired option (listed above).
5. Press <Enter> to start the test. The fixture will perform the selected self test.
6. Press <Menu> to exit the test.
Moving the Fixture to Setup Position (S/UP)
Caution: The setup position is used only by qualified service
personnel during maintenance.
To place the fixture in setup position before servicing:
1. Hold <MENU> until the display changes to
AddR
.
2. Using the up and down buttons, scroll to the
TEST
field and press <ENTER>.
3. Using the up and down buttons, scroll to the
S/UP
field and press <ENTER>. The display
will indicate
SET
NOW
while the motors are electronically locked into place.
4. Perform the appropriate maintenance procedures.