CHAPTER 3
The Menu System
Cyberlight
®
2.0 User Manual
21
Mode Menu (MODE)
Crossloading the Fixture (XLd)
The Cyberlight fixture can crossload software from one fixture to additional Cyberlight 2.0
fixtures on the same link. To crossload software:
1. Disconnect the data cable between the console and the first fixture.
2. Hold <MENU> on the master fixture (the fixture with the latest software version) until the
display changes to
AddR
.
3. Using the up and down buttons, scroll to the
MOdE
field and press <ENTER>.
4. Using the up and down buttons, scroll to the
XLd
field and press <ENTER>. The master
fixture will upload its software to all connected fixtures on the link. The slave fixtures will
display
UPLd
during the process. After the fixtures have completed the upload, they will
reset and home.
5. Notes:If the fixture(s) take longer than one minute to reset after an upload, turn off the
fixture(s) and repeat the procedure. If a new boot code was included with the latest
software, you will need to store the boot code on each fixture. Refer to “Changing Boot
Codes” on page 3-9.
Selecting Lamp Power (LAMP)
1. You can select between 2000W and 1500W to power the lamp. To select power:
2. Hold <MENU> on the master fixture (the fixture with the latest software version) until the
display changes to
AddR
.
3. Using the up and down buttons, scroll to the
MOdE
field and press <ENTER>.
4. Using the up and down buttons, scroll to the
LAMP
field and press <ENTER>.
5. Scroll to
2000
to set the power to 2000W, or
1500
to select 1500W.
6. Press <Enter> to store.