![Higen FDA5000 Series Operation Manual Download Page 101](http://html1.mh-extra.com/html/higen/fda5000-series/fda5000-series_operation-manual_2130182101.webp)
Chapter 6. Parameter Setting
6-28
6.8 Test mode parameters (Test Mode: P6--)
6.8.1 Jog Mode (P6-01)
The Jog Mode carries sub-menus related to Jog.
The Jog Mode operates even when there is no external contact signal.
Menu
Menu name
Unit
Display range
Initial value
Mode
tS-01 Jog
Command[RPM] RPM
-5000.0~5000.0
100
Set the jog operation command speed in [rpm].
UP -Key
Menu
Menu name
Unit
Display range
Initial value
Mode
tS-02 Jog
Speed[RPM] RPM -5000.0~5000.0
0
Set the actual jog operation speed in [rpm].
Motor runs clockwise if the >(right) key is pressed, and counterclockwise if <(left) key is
pressed.
6.8.2 Auto Jog (P6-02)
This is a special type of jog mode. CW or CCW run can be set with specific speed and time
even without pressing >(right) or <(left) keys.
As in the case of Jog Mode, Auto Jog operates when the motor is connected to the encoder
without external contact signal.
Menu
Menu name
Unit
Display range
Initial value
Mode
tS-11
Auto Jog Speed1
RPM
-5000.0~5000.0
100
tS-12
Auto Jog Speed2
RPM
-5000.0~5000.0
-200
tS-13
Auto Jog Speed3
RPM
-5000.0~5000.0
300
Input the auto jog mode set speed in [rpm].
[Auto Jog Speed1]
[Auto Jog Speed2]
[Auto Jog Speed3]
[Auto Jog Time1]
[Auto Jog Time3]
[Auto Jog Time2]
[Auto Jog Speed1]
[Auto Jog Speed3]