Trouble-shooting when use V5.0 

     Q: 

In  process  of  installation  of  V5.0,  computer  pops-up  a 

box to request for 64 bit driver? 

 

     A: 

After V5.0 is finished installation to PC, back to the di-

rectory folder of HiFei V5.0 from where it is installed, you will 

find the driver for 64 bit. Run the driver and finish the installa-

tion  by  hand.  Then  computer  will  notice  software  can  work 

normally.  

 

 

     

Q: 

It  pops-up  box  „  Time  out,  device  open  failure‟  when 

click on „Open Device‟ button.  

 

     

A: 

There are three possible reasons to result from this prob-

lem. 

1) 

First is wrong polarity connection between ESC receiv-

er lead and USB linker. Please check if the connection is cor-

rect  and  tight.  In  addition,  Kingkong  III  160A  and  200A  are 

OPTO,  it  is  requested  to  connect  ESC  to  battery  pack  when 

connect them to PC. 

2) 

Second reason may because ESC were 

damaged in running. In this condition,  please contact our after

-service for repair.  

3) 

At last, it  may because USB Linker is 

damaged.  

 

 

     

Q: 

It pops-up box „Invalid Com Port‟ when click on „Open 

Device‟ button. 

 

     

A: 

It because com port for ESC connection device is wrong 

or occupied by other devices. Please open „Device manager‟ of 

„My computer‟ to check the right com port number or change 

the  com  port  number  which  be  occupied  to  an  available  port 

number. Then open V5.0, select the right com port number and 

save it.   

 

 

    

Q: 

It  cannot  upload  data  and  pops-up  a  box  „C:\Program 

files\V5.0\ xxx cannot be found‟. 

 

    

A: 

It  because  ESC  run  too  short  time  and  the  logged  data 

cannot be  showed  in  window. Please clear  the  data  and  fly  it 

again for a longer time than required minimum time.  

 

 

    

Q: 

In the process of uploading data, it stops uploading and 

pops-up  an  error  box  „Program:  C:\Program  Files\Hifei  V5.0

\Hifei V5.0.exe This application has requested the Runtime to 

terminate it in an unusual way. Please contact the applications 

support team for more information.‟ 
 
     

A: 

The problem is because V5.0 is installed to „C‟ and the 

security  setting  of  „C‟  stops  the  uploading.  There  are  three 

ways to solve the problem.  1) First, if PC has more than one 

hard partitions, then change to install V5.0 to other hard disks 

from “C‟‟.  2) If PC has only one hard disk „C‟, you can try to 

install V5.0 to a flash disk.   3) Change security settings of „C‟, 

select PC user as „administrator‟ and  let all the permissions of 

writing and reading below are allowed. Save the change. Then 

try to upload data again.

 

 
        

 

Page 8

 

Summary of Contents for 100A-KIII Pro-6S Lite

Page 1: ... battery black wire Follow the instructions provided with battery connector Connect ESC to motor Suggested to solder quality and corresponding size golden bul let connectors for your motor to the motor wires coming from ESC Swapping any two motor wires connection can change rota tion direction Connect to receiver Connect the receiver lead consisted of brown red and orange small wires with a black ...

Page 2: ...power and slight ly less efficient Option 2 middle 5 20 Recommended for most mo tors Gives a good balance of power and efficiency Option 3 High 15 30 Recommended for most of higher pole count motors Option4 Auto default Recommended for most of all brush less motors Option 5 0 Option 6 2 Option 7 4 Option 8 6 Option 9 8 Option 10 10 Option 11 12 Option 12 14 Option 13 16 Option 14 18 Option 15 20 O...

Page 3: ...h as VBar Skookum MB BeastX etc Option 3 Governor ESC Internal Governor PWM rate Option 1 8 KHz default Recommended for most brushless mo tors Option 2 10KHz Option 3 12KHz Option 4 16 KHz Recommended for very low inductance motors Option 5 20 KHz Option 6 24 KHz Option 7 28 KHz Option 8 32 KHz Active FreeWheeling Option 1 default OFF Option 2 ON helicopter mode than its body diode so much less he...

Page 4: ...n Spool Up Rate indicates the startup spool up rate the default setting is Level 3 higher level numbers means to approach the head speed faster Governor Gain The default setting is grade 9 the higher grade number means the higher gain Head Speed Change Rate The default setting is standard this setting indicates the change rate between 2 different head speed switching for example throttle curve swi...

Page 5: ... pinion or Inc Dec the Desired Head Speed to get the best match results Please carefully check your heli configuration make sure the desired heed speed is under control Furthermore fill out the battery voltage and motor KV can help you find out the ESC power output match with the pre set head speed HiFei recommends for optimum the ESC output to motor about 80 power it ensure the ESC has enough res...

Page 6: ...al size Because big size font would possi bly cause software interface cannot be showed in full Connect ESC to PC Kingkong III Pro USER MANUALS www hifei com HiFei Software V5 0 operation V5 0 tab 2 Parameter setting Click on tab 2 Parameter Setting to get into programming in terface select the options you want to change by down arrow then click on Update to save the setting V5 0 tab 5 Upgrade In ...

Page 7: ...space is filled up it continue logging data indefinitely by overlapping the for mer data and do a cycle Default setting is Not Reverse Sampling rate means the times that data logger samples per second Default setting is 3ps Higher sampling rate will fill up the memory space quickly and thus reduce the logging time when in not reverse record type Sampling Rate Max logging Time Mini running Time Not...

Page 8: ...n device is wrong or occupied by other devices Please open Device manager of My computer to check the right com port number or change the com port number which be occupied to an available port number Then open V5 0 select the right com port number and save it Q It cannot upload data and pops up a box C Program files V5 0 xxx cannot be found A It because ESC run too short time and the logged data c...

Page 9: ... Dongle Connecting the cable to ESC and WiFi dongle Figure 1 Power on the ESC waiting about 30 seconds until the green LED on WIFI dongle blink Option HiFei KIII in the WLAN list of your smart termi nal Open your browser and input the default IP address password as following IP address 192 168 1 16 2015 Password 12345678 Entered into the Home Page Page 9 Reserve Mini USB Reset Attena Home Page Par...

Page 10: ...Dawn Urban Industrial Park Gang An 2 Street Cun Tan Jiang Bei Chongqing 400025 Tel 86 23 6862 1580 6862 6070 Fax 86 23 6862 6070 Note After Updated the The AP name and IP Address Please press Reset button in 1 second and release the red LED will blink in 5 seconds and go to steady light af ter that you have to re power up the WiFi dongle to make the change available ...

Reviews: