 2-1. Controller installation 

2-2. Controller Operation-Type 4

A. The controller should be installed outside of the steam room with convenience access for operations. Please

install it as near as possible to the room's door. The recommended height is 1.5meter above from the ground.

B. Dig a hole with diameter 30mm before installation, tear off the adhesive's paper behind the controller, fix the

controller and then seal the sides with sealant or silicone.

2. Operational Setting

A. On / off button: start or stop steam generator. This

button is used to turn on or shut off the power.

 

 

1) the Timer display window. It shows the remaining

time, the machine will turn off when the display

reaches "0".

 

 

2) Temperature display shows the steam room

inside temperature.

B.Light control button: To turn on or turn off the

cabin's light.

C.Setup button: Set the temperature and time.

 

 

1) Press "SET" gently and the timer display show

two figures of time, press "UP" and "Down" to set

your desired period, the machine will turn off when

the counter precipitation "0". The Time setting range

is 1 -60 minutes. Machine default time is 45 minutes.

 

 

2) Press "SET"key again, the temperature display

show two figures of temperature, press "UP" and

"Down" to set your desired temperature. The

temperature setting range is 35-55 

, Machine

default temperature is 40 

.

 

 

3) Press "SET" key once more to save the above

setting. And the setting state will return after 15s

without operation.

D. The the temperature is inside the steam room is higher than the target, the machine will stop generating steam.

The constant temperature indicator light is on and the heat indicator light is off. When the temperature lower the

desired temperature, the machine will continue to heat water untill arrive the temperature  reach target again. The

heat indicator light is on and the constant temperature indicator light is off. The steam generator will automatic

control the steam room temperature within the range of +/- 2degree.

Heat indicator light 

Temperature 
display 

On/Off  

Setting button 

Up button 

Controller- Type 

Down button 

Time display 

Constant 
temperature 
indicator light 

Sauna room light control 

Summary of Contents for Hidro-ST Series

Page 1: ...STEAM GENERATOR Hidro ST Series USER MANUAL ...

Page 2: ...HIPMENT AND HANDLING WARNING Only qualified personnel should install and maintain this equipment Unauthorized alteration or improper maintenance of this unit may release the manufacturer from any warranty claims The installation must be in accordance with the instructions in this manual and applicable local plumbing and electrical codes ...

Page 3: ...ST45 3 5 4 5 220V 1 19 4 Hidro ST60 4 2 6 220V 1 28 6 Hidro ST60B 4 2 6 380V 3 9 4 Hidro ST80 6 2 8 380V 3 12 4 Hidro ST90 8 5 9 380V 3 14 4 Hidro ST105 9 3 10 5 380V 3 16 6 Hidro ST120 10 12 380V 3 19 6 Hidro ST150 12 15 380V 3 23 6 Hidro ST180 15 18 380V 3 28 6 All specifications are subject to the latest one changes without prior notice ...

Page 4: ...st set in with strong expansion bolts or equivalent supports C The steam pipe should enter into the steam room and total length less than 6meter and set it at least 300mm above the floor or 150mm far away from the seat D The generator should be mounted in a minimum 0 25m space E The mounting location should minimize the number of bends and elbows in the steam lines F Should not be install in the c...

Page 5: ...nstallation instructions have been correctly followed and then the generator is ready for a trial operation in accordance with operating instructions Water inlet Steam outlet Safety Valve Rinse valve Cable connection Cable connection Water inlet Steam outlet Rinse valve Hidro ST105 Hidro ST120 Hidro ST150 Hidro ST180 Hidro ST30 Hidro ST45 Hidro ST60 Hidro ST60B Hidro ST80 Hidro ST90 Connect the co...

Page 6: ...hould be less than 6m The steam pipe shall slope to the steam bathroom and higher than the position of the steam head so that condensation could drain into the steam room and will not gather in the tube Furthermore the steam pipe should be insulated properly D Install the steam head complying with the instructions The user shall not touch the steam head E The water drainage channel must be opened ...

Page 7: ...ed period the machine will turn off when the counter precipitation 0 The Time setting range is 1 60 minutes Machine default time is 45 minutes 2 Press SET key again the temperature display show two figures of temperature press UP and Down to set your desired temperature The temperature setting range is 35 55 Machine default temperature is 40 3 Press SET key once more to save the above setting And ...

Page 8: ...verheated environment 2 Overheating will present a scald hazard Must be careful while entering the steam bathroom If the steam room is overheated the bather shall get out of the room immediately Regular checking is requested to avoid the leakage or parts damage for the steam head pressure relief valve accessories connections of hermetic parts 3 1 Water rinse Rinse once for each few hours or after ...

Page 9: ...unction 1 Switch off circuit protector 2 Shut off water supply valve 3 Call our maintenance service center There are user serviceable parts in the generator All repairs should be performed by a qualified service person The Trouble Shooting Guide below is for general reference only PROBABLE CAUSES ACTION TO BE TAKEN No steam while controller has been turned ON 1 Steam generator hasn t been connecte...

Page 10: ...outer wall of the steam room can be able to withstand the great temperature changes 5 Voltage of electric source and phase electricity 220V 380V a single phase electricity or three phases electricity Lower voltage causes less steam 6 When installing the steam generator we recommend using a larger size cable than normally used C Announcement The above messages are recommendations only These recomme...

Page 11: ...ch kind of design reduces the space of the steam bathroom 4 Easy cleaning and drainage must be taken into consideration when designing the floor drainage For the consideration of safety the floor must be slipping proof 5 The heights of steam bathroom must be limited to 2 4m or below Heights over 2 4m will cause a high or adequate temperature around the ceiling while the temperature around the floo...

Reviews: