3. Maintenance
Clean the steam generator regularly according user’s water quality and using frequency:
A. Electrical shock hazard------there are no user serviceable parts in the generator. All installations and relevant
services shall be performed by qualified personnel to avoid electrical shock hazard,.
B. Steam bathing time should be less than half an hour. Bathing too long may cause heart beating too fast, light
heartache, feeling weak or dizzy. Should the bather stop bathing immediately as soon as the above symptoms occur.
C. Steam bath may cause tension to the bather. Thus, one who is one of the followings should be directed by
physician:
1). Being pregnant
5). After drinking
2). Having heart disease
6). After taking medicine
3). Having high blood pressure
7). Diabetes
4). Having circulation system disease
8). Not feeling well
D. Children must be accompany of adult in taking sauna bath.
E. Risk of scald: Must not touch the steam head or trim during operation , Stay at least 30cm away from the hot steam
escaping head. It is recommended that one should not use the generator continuously for a long time, because:
1). The building materials may get damaged under an overheated environment.
2). Overheating will present a scald hazard. Must be careful while entering the steam bathroom. If the steam room
is overheated, the bather shall get out of the room immediately.
Regular checking is requested to avoid the leakage or parts damage for the steam head, pressure relief valve,
accessories, connections of hermetic parts
3-1. Water rinse
Rinse once for each few hours or after every steam bathing, depends on different situations.
A. Disconnect the electricity power.
B. Open the rinse valve and water supply valve.
C. Connect the electricity power.
D. Rinse for 10 minutes.
E. Switch off the electricity power, close the water supply valve and the rinse valve.
3-2. Citric acid cleansing
A. Mix 50-80 grams of citric acid with one liter water.
B. Put the steamer upside down with the pipe up, then take off the Rinse valve.
C. Inject the blend citric acid into the steam tank through a funnel, as figure 2.
D. Set up the rinse valve and turn it off, then put the steam on a flat ground for motionless for 20 minutes. As figure 3.
E. After 20 minutes, turn on the rinse valve and let the citric acid flowing out.
F. Open the water supply valve.
G. Connect the electricity power.
H. Rinse for 5 minutes.
I. Switch off the electricity power, shut off the water supply valve and the rinse valve.
Citric acid
Figure 2
water outlet
Figure 3
Rinse
valve
WARNING