Work mode setting
Auto-work mode
Enable
Enable the auto-work mode
Protocol type
TCP
CS mode
Server
Server address
-
TCP connection
timeout
120
Default connection:
When it’s set to TCP server
,
the default
timeout is 120second
Advanced wireless setting
Network mode
Infra
Network mode is Infrastructure
Create adhoc
when network
does not exist
- -
BG mode
B/G
Wireless mode is BG fixed
Maximum rate
36M
The Maximum sending rate is 36M
BSSID
Auto
Forbid to fix the BSSID address of wireless
network
Channel
Auto Detect
the
operating channel of wireless
network automatically
Auto retry
255
Retry for ever automatically
Wirelss roam
Disable
Forbid to do the wireless roam
Channel list
0x3fff
1~14 channels
Serial setting
Baud rate
115200
Data bits
8 bits
Stop bits
1 bit
Parity bit
None
The data format of serial is set to:
Baud rate is 115200bps;
8 bits of data bits
1 bit of stop bits
No parity of parity bit
The setting of transparent mode
Auto framing
length
512
The length is 512 bytes
Auto framing
period
500ms
The period is 500ms
Escape
character
0x2B
The character is 0x2B,that is “+” in ASCII