11.  PLEASE OBSERVE  THE PANEL SAFETY  WARNINGS 
PRINTED ON  THE  REAR  PANEL.

3.  SIGNAL/LIMIT: 

 A green illumination indicate  the presence of 

s

a signal.  The 

 will change to red when the onboard limiter is 

LED

active. Occasional blinking of the red Limit led is ok, but continuous 
illumination could result in reduced audio quality.

12.  POLE SOCKET: 

 If a standard 35mm pole is used, please 

observe the following precautions:

2.  VOLUME:

  Use to set the overall output level of the TRM.  

To rectify this, either reduce VOLUME control on the TRM cabinet or 
reduce the level of this incoming audio.

FOH

 (Front of House) - For use on a pole or tripod as a front of 

house system.  

6.  LINK OUTPUT: 

 A balanced XLR output connected in parallel 

to the Combi Input. Use to pass the signal along to another active 
cabinet. 

8.   VOLTAGE SELECT SWITCH: 

 Although every effort has 

been made to set to the correct voltage (for the region the product 
is supplied to), please check before powering up.

9.  MAINS SWITCH:

  Turns the TRM on and off.  Ensure the 

Volume control is set to minimum before switching on or off.

4.  POWER INDICATOR:

  Illuminates when the unit is connected 

to a suitable mains source and the Power Switch is set to on.

7.

 

 GND LIFT:

  A Ground lift has been provided to reduce the 

potential problem of earth loops when connecting to other 
equipment.  This control is to be used in conjunction with the Link 
Out.

MONITOR

 - For use as a floor standing monitor.

 

5.  MODE (PRESHAPE):

  A choice of two optimised EQ settings 

depending on the desired use:

10.  MAINS INLET IEC and FUSE:

  Input for connection of an 

appropriate mains lead. 

1.  COMBI INPUT:

  A line level balanced input compatible with 

balanced and unbalanced XLR and jack signal leads. 

 

Only replace the fuse with the type indicated on the rear 
panel

!

Please note: 

The VOLUME control and MODE control do not have 

any effect on the LINK OUTPUT.

Ÿ

It is the users responsibility to ensure this product is correctly 
installed and used in a sensible and safe and manner. 

Ÿ

Ensure the top cab is smaller/lighter than bottom if using a pole.

Ÿ

Don't overextend poles/tripods; ensure at least 4 x the pole 
diameter is still inside the outer pole.

Ÿ

Make sure the legs have a good splay on tripods, but do not 
obstruct doorways or other access-ways.

Please note: 

 As this is a balanced input, a stereo signal cannot be 

connected to this socket. 

CONTROL PANEL

9

6

PRESHAPE: EQ MODES

MON

FOH

12

4

5

8

9

11

2

7

MODEL: TRM-1201

10

1

6

3

EN

Summary of Contents for Tensor TRM-1201

Page 1: ...ACTIVE STAGE MONITOR DESIGNED AND ENGINEERED IN THE UK WWW HHELECTRONICS COM TRM 1201...

Page 2: ..._____________________________ SPECIFICATION 5 _____________________________ INTRODUCTION GETTING STARTED 6 _____________________________ CONTROL PANEL 4 _____________________________ GENERAL INSTRUCTI...

Page 3: ...a la lluvia o humedad este aparato Antes de usar este aparato lea mas advertcias en la guia de operacion Afin de prevenir les risques de decharge electrique ou de feu n exposez pas cet appareil a la p...

Page 4: ...over 15 Never break off the ground pin Connect only to a power supply of the type marked on the unit adjacent to the power supply cord The U S Government s Occupational Safety and Health Administrati...

Page 5: ...nitoring solution The HH Tensor TRM 1201 Engineered in the UK to deliver power performance and reliability 100 120V setting VOLTAGE SELECT 100 120V 220 240V 220 240V setting VOLTAGE SELECT 100 120V 22...

Page 6: ...ing on or off 4 POWER INDICATOR Illuminates when the unit is connected to a suitable mains source and the Power Switch is set to on 7 GND LIFT A Ground lift has been provided to reduce the potential p...

Page 7: ...GND LIFT MODE STAGE MONITOR MODE For best results set the MODE switch to MONITOR on the TRM 1201 cabinets TRM 1201 STAGE MONITOR TRM 1201 STAGE MONITOR 11 FRONT OF HOUSE MODE In this example the MODE...

Page 8: ...solder pin view shown Balanced XLR 2 1 3 GND FEMALE 1 2 3 GND MALE 6 3mm mono jack 1 GROUND 2 HOT 3 COLD Unbalanced signal cables can be used for interconnects but are more sensitive to noise pickup e...

Page 9: ...20 240V 50 60Hz User Switchable AC Power Consumption 300W AC Power Inlet IEC C14 INLET Enclosure Cabinet Acoustically optimised Plywood cabinet with integrated carry handles Finish Painted Black Monit...

Page 10: ...els des produits destin s alerter l op rateur des zones ou des pr cautions suppl mentaires pouvant tre n cessaires 18 Cet quipement lectrique ne doit en aucun cas tre en contact avec un quelconque liq...

Page 11: ...et jack sym triques et asym triques Notez qu il s agit d une entr e sym trique un signal st r o ne peut pas tre connect cette prise 2 VOLUME Sert r gler le niveau de sortie global du TRM Pour rem die...

Page 12: ...tigkeit mit der derVerst rker zwischen geraden und schr gen R cken Positionen bewegt werden kann verwenden Sie nur denVerst rker auf einer ebenen stabilen Oberfl che NICHT denVerst rker auf einem Schr...

Page 13: ...signed and Engineered in the UK by HH Electronics LTD 2022 HH Electronics Ltd ACTIVE STAGE MONITOR LIVE SOUND BENUTZEROBERFL CHE PRESHAPE EQ MODES 12 DE 13 4 5 8 9 11 2 7 MODEL TRM 1201 10 1 6 3 MON F...

Page 14: ...no poner objetos que contengan l quidos como vasos sobre el aparato 1 Lea estas instrucciones 3 Haga caso de todos los consejos 11 Usar solamente componentes y accesorios proporcionados por el fabrica...

Page 15: ...ELTRASERO 12 ENCHUFE DE POSTE Al utilizar un tr pode est ndar de 35 mm observe las siguientes precauciones 9 INTERRUPTOR DE FUERZA Enciende y apaga el TRM Aseg rese de que el control de volumen est co...

Page 16: ...o Unido Se as cores dos fios do cabo de alimenta o da unidade n o correspondem com os terminais na ficha fa a o seguinte a O fio que colorido verde e amarelo tem de ser ligado ao terminal que est marc...

Page 17: ...ido para reduzir o problema potencial de realimenta o do sinal de terra ao conectar a outro equipamento Este controle deve ser usado em conjunto com a sa da Link caso o problema ocorra MONITOR Para us...

Page 18: ...Engineered in the UK by HH Electronics LTD 2022 HH Electronics Ltd ACTIVE STAGE MONITOR LIVE SOUND 4 9 I 15 16 2 17 a E b N c L 12 13 1 14 10 7 11 18 8 3 6 5 20 19 OSHA OSHA 2000m 2000m 21 CAUTION WAR...

Page 19: ...HH Electronics LTD 2022 HH Electronics Ltd ACTIVE STAGE MONITOR LIVE SOUND PRESHAPE EQ MODES 12 CN 19 6 XLR Combi 2 TRM 1 1 4 TRM 4 5 EQ FOH 3 LED led 7 MIX OUT 9 TRM 8 11 10 12 35mm 35mm 4 4 5 8 9 11...

Page 20: ...Designed and Engineered in the UK by HH Electronics LTD 2022 HH Electronics Ltd ACTIVE STAGE MONITOR LIVE SOUND KR CAUTION WARNING 20...

Page 21: ...REVISION 1 00 Model number Serial number Place of purchase Date of purchase hhelectronics www hhelectronics com hhelectronics hhelectronics...

Reviews: