Petrol Generator
Precautions
The generator can constitute a hazard to users, nearby personnel and property unless the following precautions
are observed during operation:
• Ensure that you know how to stop the engine in an emergency.
• Exhaust fumes are poisonous and can kill.
- Do not
operate the generator in a con
fi
ned area.
- Ensure
that the area surrounding the machine has no restrictions that would prevent an adequate
fl
ow
of clean, ambient air.
• The generator should be operated in an open space with free air
fl
ow on all sides, at least one
metre from other equipment and buildings. The surrounding area should be clear of any combustible
material.
• Fuel is highly
fl
ammable, when refuelling:
- Do not
run the engine.
- Do not
smoke.
- Avoid
over
fi
lling the fuel tank.
- Wipe up
any fuel spilt on the machine and move the equipment away from the area where fuel has
been
spilt.
- Store
fuel in approved containers only and do not expose to direct sunlight.
• Parts of the engine, and particularly the exhaust system will get very hot during use, and will remain hot
for some time after the generator has stopped.
• Do not use the equipment with loose or missing components or guards.
• Additional care should be applied if using the generator in damp or wet conditions.
• The throttle control lever is preset to the correct engine speed and must not be adjusted, otherwise
damage to equipment or the generator may be caused and will invalidate the warranty.
• Regularly inspect the condition of trailing cables and integrity of connectors. Only use correctly rated cable
and standard plugs of suitable capacity for the application.
• During servicing, follow HSE recommendations regarding the handling and disposal of contaminated oil
products.
Earthing
The earth pins of the output socket(s) are electrically connected to the metalwork of the generator.
VRP80-TIN12-TL 110V CTE with centre tap to earth.
VRP96D-TL has the neutral connection
fl
oating and not tied to earth.
VRP96T-TL has a star neutral point which is
fl
oating and not tied to earth.
Further advice on earthing can be found in the following Health & Safety Executive publications (available from
HMSO):
• GS27 Protection Against Electric Shock
• GS24 Electricity on Construction Site
• PM53 Emergency Private Generation