Dehumidifier DT 860
40 / 55
EN
–
During dehumidifying, the air in the room is
heated. In small rooms, this can substantially
increase the room temperature.
As a rule, room temperature between 20
°C
and 27
°C provide the best conditions for ef-
ficient drying. The room temperature must not
exceed 38
°C or drop below 1
°C, as the de-
vice is otherwise unable to work properly (see
also
16
Running and operating
the device
CAUTION
Risk of infection
The condensate may be contaminated with path-
ogens.
a)
Never drink the condensate.
b)
Avoid leaving condensate in the collecting
vessel or in the condensate discharge hose
for a longer period of time. Regularly pump
off the condensate.
Attention
Damage to device from improper de-icing
During operation, the evaporator may become
iced up.
a)
In this case, run the automatic defrosting
function.
b)
Never attempt to remove the ice with a
sharp-edged implement.
Before switching on the device
a)
Make sure that the device is not standing on a
wet surface, and that it is in a safe upright
position.
b)
Check the power cable for defects.
c)
Ensure that the device is connected to a fused
socket of the correct voltage (see
d)
Make sure that the condensate can drain off
safely. Check whether the condensate tank is
inserted properly.
Place the free end of the condensate dis-
charge hose in a drain or in an
empty
collect-
ing container of suitable capacity.
e)
If necessary, call up the operating hours
counter and document the current counter
reading (to reset the counter, see
f)
If necessary, read the kW/h value on the
power meter and document it.
Switching device on
Fig. 17:
Switching device on
1 ON/OFF indicator
2 WORK indicator
3 FULL indicator
4 SET+ button
5 SET- button
6 ON/OFF button
a)
Press the ON/OFF button.
The ON/OFF indicator is lit in green.
NOTICE! If the compressor is not yet
ready for operation, the WORK indicator
flashes.
When the compressor is ready and the
WORK indicator no longer flashes, the de-
vice is automatically started.
Press the SET + or SET
–
button to set the
required humidity level.
6
1
2
3
5
4
Summary of Contents for 1110584