The Aruba 7010 Mobility Controller requires a minimum of 6 TELs to be applied as follows:
To Detect Opening the Chassis Lid Top
•
Spanning the front bezel and the chassis lid, as shown in Figure 9 (Label 1).
To Detect Opening the Chassis Lid Bottom
•
Spanning the bottom and the chassis lid, as shown in Figures 10 and 11 (Labels 3, 4, 5 and 6).
To Detect Access to Restricted Ports
•
One label (label 2) spanning the RJ-45 and mini-USB serial ports, as shown in Figure 10. Press down on this
label to ensure that it adheres to a sufficient area of the front bezel. The RJ-45 port is raised relative to the bezel
so there will be some air gap under the label in this area. However, the air gap should not be larger than 2-3mm.
Figure 9 Required TELs for the Aruba 7010 Mobility Controller – Top
Aruba 7XXX Series Controllers FIPS 140-2 Level 2 Security Policy