General information

The Green 250 pellet stove must only be instal-
led in residential environments. 

The stove installation must be in accordance 
with national, European and possibly local re-
gulations. You must follow local regulations with 
regard to installation of chimney and connection 
to the chimney. Be aware that it is always the 
owner himself who has responsibility for ensu-
ring that applicable rules are complied with.

A modern pellet stove places heavy demands 
on the chimney due to the high efficiency. It may 
be necessary to enhance or even replace an old 
chimney.
The stove has fully automatic control, ensuring 
controlled combustion. The control system ma-

nages the ignition process, three heat levels and 

shutdown, ensuring that the stove functions 

correctly.

Placement

The position of the stove within the home will 

have a major impact on heat distribution.

Before deciding where to place the stove, it is 

important to consider the following:
a)  The air supply for combustion must   

 

 

come from a ventilated room or an open    

 

outdoor area.

b)  Installation in a bedroom is not advised.

c)  The stove must be installed in a spaci- 

 

 

ous and central location in the house to    

 

ensure the best heat distribution.

Safety information

The Green 250 pellet stove must be installed by 
a technician who has been trained by Heta A/S. 

Please read these instructions regarding use 

and maintenance carefully before installing and 

lighting the stove! If you need further informa-

tion, please contact the dealer from whom you 
purchased the stove.

NOTE

The stove has extra protection in 

line with power regulations, and 

must have an earthed electrical 

connection.

Liability

By providing these instructions, Heta A/S dis-
claims all liability, both personal and statutory, 
for any accidents that may arise due to failure 
– either fully or in part – to observe the instruc-
tions enclosed herein.
Heta A/S disclaims all liability in relation to in-
correct use of the stove, abnormal usage by the 
customer, unauthorised replacement and/or re-
pair, or the use of non-original spare parts for 
this model.

The manufacturer disclaims all liability, both 

personal and statutory, direct and indirect, 

attributable to:

•  Inadequate maintenance

•  Failure to observe the instructions in this    

 manual

•  Failure to observe safety directions

•  Irregular installation with failure to ob  

 

  serve applicable standards in the  

 

 

  destination country

•  Installation carried out by unqualified or  

 

  untrained personnel

•  Replacement or repair not authorised by    

  the manufacturer

•  Use of non-original spare parts

•  Extraordinary events

If you have any questions con-

cerning your pellet stove, Heta 

strongly recommends that you 

contact your dealer immediately.

Floor

You must ensure that the floor can support the 
weight of the stove and a top-mounted steel 
chimney.

In front of the pellet stove, the substrate must 
consist of non-combustible material, for ex. Ste-
el/glass plate, stone or tile floor. The size of the 
non-combustible surface must follow the appli-
cable national and local regulations. 

Summary of Contents for SCAN-LINE GREEN 250

Page 1: ...1 OPERATING AND INSTALLATION INSTRUCTIONS DANISH DESIGN DANISH QUALITY DANISH PRODUCTION www heta dk EN SCAN LINE GREEN 250...

Page 2: ...Jupitervej 22 DK 7620 Lemvig Phone 45 9663 0600 E mail heta heta dk Copyright 2014 Heta is a registered trademark of Heta A S 08 06 2022 0037 1795 Version 1 0 Printed in Denmark Subject to printing e...

Page 3: ...n transport or handling damage of the often heavy stoves can occur It is impor tant that upon receipt check your Heta product completely and report any damage or defects to your dealer The packaging m...

Page 4: ...rk Produk ons r 2016 Produkt beskrivelse Produk onsnummer Afstand l br ndbart materiale bag ovn Afstand l br ndbart materiale side af ovn Afstand l m bel Middel CO emission nominel last ved 13 O2 Midd...

Page 5: ...urfaces 3 Connect the stove to the mains using the supplied cable 4 Set the desired settings using the display See page 6 5 Feed the pellets through as mentioned below 6 Start the stove See page 7 Man...

Page 6: ...only be handled using the appropriate protection Transparent protective film It is recommended that you remove the protec tive film before using the Display to guarantee the best performance of the s...

Page 7: ...enu overview 1 Swipe for at t nde ON Slide to turn on off 2 Justering Power Thermostat Combustion Manuel pellet setting feed Power P3 5 Calibrazione Ventilatore Power level P4 P5 Auto Power level 2 3...

Page 8: ...Thermostat Temperature 40 3 5 10 24 22 23 25 26 Temperature 4 Combustion setting Combustion levels 5 1 2 4 1 3 4 Combustion levels 8 To select room temperature...

Page 9: ...5 Manual pellet feed Manual pellet feed 00 00 Manual pellet feed Manual pellet feed Important The burn pot must be empty for wood pellets before start up See page 5 9...

Page 10: ...anguage Adjusting pellet quantity Only for service technician Brightness Standby brightness Display stand by Screen Saver Control panel address Restart Display Alarm with sound Delete errors System In...

Page 11: ...e three possible programs Start Stop Select the start and stop time for the program 22 C Er52 TIMER DAILY DAILY WEEKLY WEEKDAYS WEEKEND 03 15 04 30 09 00 11 30 21 15 23 30 DAILY Monday Tuesday Wednesd...

Page 12: ...c mode the system selects the com bustion effect In manual mode you select the desired effect yourself Manually set the desired heat level from 1 to 3 or select automatic mode Setting the desired temp...

Page 13: ...flue pipe must be kept free from ash and soot Clean the pipe with a clea ning brush and vacuum the ash room Remove the chimney fan and clean any ash or soot off the housing and blades Cleaning the Pre...

Page 14: ...to remove ash See page 14 To remove all the stones first remove A then C D E F and finally B Fig 4 The stones are put back in reverse order NOTE That the vermiculite stones are a porous material and m...

Page 15: ...2 2 1 4 8 1 3 5 6 7 15 Ash cleaning must be monthly Ash cleaning semi annually or annually...

Page 16: ...y still be partially usable However it will not be fully functional Contact a professional as soon as possible In the event of an error message the error screen will continue to flash and the problem...

Page 17: ...t contribute to the combustion process rather it will reduce the volume of air used for combustion The ef fect on diminishing of the combustion process will be greater the fewer pellets are left in th...

Page 18: ...ow is redu ced and fewer pellets are delivered to the stove This process will normally last for a few minutes when the flames may burn dark yellow or orange until optimal combustion is re established...

Page 19: ...eted contact dealer Er16 Motherboard error messages Fault in the stove s internal communication Disconnect and reconnect the power the oven if it does not help contact dealer Er17 DP flow adjustment e...

Page 20: ...ponent of the wood pel let as moisture helps to ensure a durable pellet and prevent dust Choose a moisture content of 6 8 for the best result ASH CONTENT When you burn wood pellets a residue will oc c...

Page 21: ...008 0058 M6x8 Hexagon socket buttom head screw BN 19 Black 1 2 0008 1002 M6x6 Hexagon socket set screw BN 30 FZB 2 3 0008 2005 M5x10 Hexagon socket head screw BN 610 RF A2 2 4 0008 2304 M4x6 Hexalabul...

Page 22: ...steel burn pot Any damage arising from inappropriate installation and or treatment of the stove and or customer errors Damage caused by incorrect use Freight costs in connection with repairs under th...

Page 23: ...ion instructions 24 General information 24 Placement 24 Safety information 24 Liability 24 Floor 24 The chimney connection 25 Chimney draft 25 External air supply 25 Installation 25 Distance Provision...

Page 24: ...efore installing and lighting the stove If you need further informa tion please contact the dealer from whom you purchased the stove NOTE The stove has extra protection in line with power regulations...

Page 25: ...er if the re is a strong chimney draught over 20 pascals we recommend a draught stabiliser be installed Otherwise the chimney will overrun the flue va cuum pump resulting in too much combustion The st...

Page 26: ...all is made of non flammable material the stove in principle may be placed flush against it We recommend a minimum of 5 cm to facilitate air circulation around the stove If in doubt contact your chimn...

Page 27: ...27 Disassembling soapstone before installation 1 2 1 2 3 1 2...

Page 28: ...Installation of HETA climate Wi Fi Accessory 546 1107 87 601 205 205 90 90 549 1034 979 440 350 127 28 Stovedrawings measurments...

Page 29: ...29 Installation of external fresh air kit External fresh air 80 mm 6000 026126 100 mm 6000 024610 1 3 4 Accessory 2...

Page 30: ...moved the room Flex pipe fixed pipe must be permanently mounted on the fresh air connection the joint must be tight Flex pipes fixed pipes must be mounted on the outside the fresh air connection Conne...

Page 31: ...heat output th nom 95 Useful efficiency at minimum heat output th min 97 Auxiliary electricity consumption At nominal heat output elmax 0 06 kW At minimum heat output elmin 0 04 kW In standby mode elS...

Page 32: ...32...

Reviews: