10
Technical data
Setting AutomaticDimControl (ADC)
“PROFESSIONAL”, “HIGHPOWER” equipment package
For automatic dimming of the luminaire during the late night
hours, you can select from 16 predefined dimming programs
on rotary switch “A” of the LED KIT. Here the “V”
value identifies the start of dimming in the hours
before midnight and the “N” value identifies the
return to non-dimmed operation in the hours after
midnight. When dimmed, the electric power con-
sumption is reduced to around 35% and the lumi-
nous flux to around 40%. Example: Position “8” means that
the luminaire is automatically dimmed between approx. 11
pm and 6 am. In switch position “1”, version VS.02 lights up
with 100% as long as 0V is present at its PSt input. But if 230V
is applied to the PSt input, it switches to dimming mode. The
switch position “2” causes permanent dimming with version
VS27 or the opposite logic with VS02. In pos. “15”, the LED KIT
executes “Flash” mode in which the light intensity changes
between 30% and 100% in a cycle of 1s to 2s. Flash operation
is intended in particular for attention-raising illumination of
danger zones. (Please avoid disturbing local residents!)
Automatic Dimming
teach-in 3 days
N
V
A
0h
0h
0h
1h
2h2h2h3h3h
0V
3h
1h
1h
6h
5h
4h
5h
4h5h6h4h5h
230V
6h
4h
6h
16
14
13
12
11
10
9
8
7
6
5
4
3
2
1
dim
A
dim = 35%
Control
1
.
15
.
13
.
11
.
9
.
7
.
5
.
3
.
'Mid-Night'
On
Off
N
V
100%
dim
PSt
flash
4h
6h
15
dim
100%
100%
Note
If mains are frequently subject to peaks in vol-
tage, take additional relevant surge protection
measures as necessary.
Elect. connection
0.3m connection cable 3 x 0.75mm
2
Dimensions
Ø 95/H272mm; H287mm
1)
Weight
1,100g
Ingress protection
IP20
Ingress protection of
luminaire
≥ IP43
Ambient temperature
-35....+35°C
Volume of lamp space
≥ 14dm³
Nominal voltage
220-240V AC 50Hz
2)
Power factor
> 0.9
Protection rating
II
Overvoltage protection
6KV (surge)
Nominal power [W]
Asym
Sym
HIGHPOWER
23-28
32-36
PROFESSIONAL
16-19
24-28
BASIC
16
24
Luminous flux with directional
optics [klm]
Asym
Sym
HIGHPOWER
2.5
constant
3.5
constant
PROFESSIONAL
1.8
constant
2.5
constant
BASIC
1.8
2.5
Colour rendering index (CRI)
> 80
Conformity
CE
Special equipment
TempSafe (TS)
overtemperature protection
Constant Flux (CF)
constant luminous flux over 50,000hr
AutomaticDimControl (ADC)
1)
The LED KIT is basically suitable for use in systems where
dimming is controlled by reducing voltage and/or varying
frequency and works independently of the voltage/frequency
conditions with a constant light output. We would recommend
investigating suitability for use on a case by case basis.
Please note details on the type plate!