1006 SERIES 
HEAVY DUTY ELECTRIC STRIKES

Hanchett Entry Systems, Inc.

22630 N. 17th Ave.

Phoenix, AZ  85027

www.hesinnovations.com

1-11/16

[42.86]

3-3/8

[85.70]

1-1/2

[38.10]

1-3/4

[44.44]

2-1/16

[52.39]

1006 SERIES DIMENSIONS

DIMENSIONS:

INCH/MM

AD, HD, ND, TD -

OPTION

FACEPLATE

A, H, HT, N,T -

OPTION

FACEPLATE

AM, HM, NM -

OPTION

FACEPLATE

KM - OPTION

FACEPLATE

Z - OPTION 

FACEPLATE

J, E - OPTION

FACEPLATE

K - OPTION 

FACEPLATE

KD - OPTION 

FACEPLATE

1-23/32 

[43.64]

1-37/64  

[40.08]

2-7/8  

[73.02]

1-9/64

[28.83]

1/8

[3.17]

1-15/32  

[37.29]

1-25/64  

[35.48]

5/16

[7.79]

3-1/8  

[79.37]

7/8  

[22.23]

19/32

[15.46]

1-15/32 

[37.29]

1-3/32 

[27.81]

5/32

[3.97]

3-1/8  

[79.37]

23/32

[18.26]

29/32

[23.39]

1-11/32  

[34.11]

27/32

[21.46]

NOTE: Drawings are not to scale.  This information is subject to change without notice.  For questions, consult HES technical service helpline, 800-626-7590.

R - OPTION 

FACEPLATE

1-3/4

[44.45]

27/32

[21.46]

23/32

[18.22]

4-1/8

[104.78]

2-1/8

[52.39]

3/4

[20.33]

3/8

[10.68]

3-3/8

[85.70]

4-7/8

[123.83]

5/8

[15.88]

1-1/4 

[31.75]

1-11/32 

[34.11]

23/32

[18.14]

4-7/8

[123.83]

4-1/8

[104.78]

1-1/16

[26.72]

©HES 2005

1

4036006.001 rev B 

CL

= center line of faceplate 

(2nd line = center line of opening)

INSTALLATION INSTRUCTIONS • 

Please read carefully before attempting installation.

Technical Service Dept. Helpline 800-626-7590 623-582-4626

Summary of Contents for 1006 series

Page 1: ...8 79 37 7 8 22 23 19 32 15 46 1 15 32 37 29 1 3 32 27 81 5 32 3 97 3 1 8 79 37 23 32 18 26 29 32 23 39 1 11 32 34 11 27 32 21 46 NOTE Drawings are not to scale This information is subject to change without notice For questions consult HES technical service helpline 800 626 7590 R OPTION FACEPLATE 1 3 4 44 45 27 32 21 46 23 32 18 22 4 1 8 104 78 2 1 8 52 39 3 4 20 33 3 8 10 68 3 3 8 85 70 4 7 8 123...

Page 2: ...5 73 4 7 8 123 83 3 1 2 88 9 3 8 9 53 3 8 9 53 4 1 8 104 77 12 24 UNC THREADS STRIKE LOCK VERTICAL CENTERLINE 5 8 15 88 1 1 4 31 8 MORTISE LOCKSET STRIKE PLATE MORTISE LOCKSET DOOR STRIKE JAMB DESCRIPTION METAL JAMB INSTALLATION FOR 1006 SERIES FACEPLATES METAL JAMB INSTALLATION FOR 1006 D SERIES FACEPLATES 4 1 8 104 77 3 3 8 85 72 4 7 8 123 82 1 1 4 31 75 1 11 16 42 86 12 24 UNC THREADS Cutout di...

Page 3: ...dard UL 1034 listed for 1500 lbs static strength rating 70 foot lbs dynamic strength rating 250 000 cycles endurance rating Note At the request of HES this model was tested and verified by UL for the following voluntary not required ratings 3 000 lbs static strength rating 2 000 000 cycles of operation Wiring diagram for 12 24 volts 12 VOLT DC 24 VOLT DC FIG A FIG B NOTE The 1006 is supplied as a ...

Page 4: ...2005 4036006 001 rev B 1000 Series Full Keeper Shims Designed to provide horizontal adjustment to reduce the width of the strike cavity Install one or both of the shims on the inside of the keeper as needed ...