ELECTRICAL RATINGS 

Continuous Duty

FOR SOLENOID

24 VDC (+ 10%)  

12 VDC (+ 10%) 

Resistance in Ohms

100

25

Watts Seated

6

6

Amps Seated

.24

.48

-

CAUTION!

Before connecting any device at the installation site, verify input voltage and current using a

multimeter.  Many power supplies and transformers operate at higher levels than listed.  Any input voltage
exceeding 10% of the solenoid rating may cause severe damage to the unit and will void the warranty.

For any questions regarding this information, call our Technical Service Line at 1-800-626-7590

Solenoids are rated at +/- 10% indicated value

FIVE YEAR LIMITED WARRANTY

1006 LATCHBOLT MONITOR:

LBM

WIRING COLOR CODE

White - Common
Orange - NO (normally open)
Green - NC (normally closed)

LBSM

WIRING COLOR CODE

Brown - Common
Blue - NO (normally open)
Yellow - NC (normally closed)

• U.L. and U.L.C. listed for 

fire door accessory, category 

10C (file #843X), for use with 3 

hour “A” labeled doors (fail 

secure only)

• U.L. listed for burglary 

resistance, category 1034 

(file #51WK)

• ANSI A250.13-2003 

Windstorm Resistant

U.L. Tested 

Standard UL 1034 listed for:

•  1500 lbs. static strength rating

•  70 foot-lbs dynamic strength

rating

•  250,000 cycles endurance rating

Note:  At the request of HES this

model was tested and verified by

UL for the following voluntary

(not required) ratings:

•  3,000 lbs static strength rating

•  2,000,000 cycles of operation

Wiring diagram for 12/24 volts

12 VOLT DC

24 VOLT DC

FIG. A

FIG. B

NOTE:  The 1006 is supplied as a 12 volt

DC unit.  For 24 volts DC, see 

figure B.
INSTRUCTIONS:

1. Cut the violet and black wires.
2. Splice the violet and black wires 

together that are coming out of the 

strike. Connect the violet and black 

wires together with connector.

3. Individually cap the remaining 

two wires coming out of  the pigtail.

4. The unit is now 24VDC.

(Wiring methods and materials shall be in

accordance with the National Electric

Code, ANSI/NFPA 70, 1996.  This unit

must be powered from a UL listed limited

energy power source.)

RED

VIOLET

BLACK

RED/GREEN

RIB

RED

VIOLET

BLACK

RIB

BLACK

RED/GREEN

VIOLET

©HES 2005

3

4036006.001 rev B 

-

Optional LBM/LBSM Wiring Information

(LBM/LBSM ordered separately)

MINIMUM WIRE GAUGE 

Solenoid Voltage

REQUIREMENTS

24 VDC

12 VDC

200 feet or less

18 gauge

18 gauge

200 - 300 feet

18 gauge

16 gauge

300 - 400 feet

16 gauge

14 gauge

Summary of Contents for 1006 series

Page 1: ...8 79 37 7 8 22 23 19 32 15 46 1 15 32 37 29 1 3 32 27 81 5 32 3 97 3 1 8 79 37 23 32 18 26 29 32 23 39 1 11 32 34 11 27 32 21 46 NOTE Drawings are not to scale This information is subject to change without notice For questions consult HES technical service helpline 800 626 7590 R OPTION FACEPLATE 1 3 4 44 45 27 32 21 46 23 32 18 22 4 1 8 104 78 2 1 8 52 39 3 4 20 33 3 8 10 68 3 3 8 85 70 4 7 8 123...

Page 2: ...5 73 4 7 8 123 83 3 1 2 88 9 3 8 9 53 3 8 9 53 4 1 8 104 77 12 24 UNC THREADS STRIKE LOCK VERTICAL CENTERLINE 5 8 15 88 1 1 4 31 8 MORTISE LOCKSET STRIKE PLATE MORTISE LOCKSET DOOR STRIKE JAMB DESCRIPTION METAL JAMB INSTALLATION FOR 1006 SERIES FACEPLATES METAL JAMB INSTALLATION FOR 1006 D SERIES FACEPLATES 4 1 8 104 77 3 3 8 85 72 4 7 8 123 82 1 1 4 31 75 1 11 16 42 86 12 24 UNC THREADS Cutout di...

Page 3: ...dard UL 1034 listed for 1500 lbs static strength rating 70 foot lbs dynamic strength rating 250 000 cycles endurance rating Note At the request of HES this model was tested and verified by UL for the following voluntary not required ratings 3 000 lbs static strength rating 2 000 000 cycles of operation Wiring diagram for 12 24 volts 12 VOLT DC 24 VOLT DC FIG A FIG B NOTE The 1006 is supplied as a ...

Page 4: ...2005 4036006 001 rev B 1000 Series Full Keeper Shims Designed to provide horizontal adjustment to reduce the width of the strike cavity Install one or both of the shims on the inside of the keeper as needed ...

Reviews: