1.2 Device description
A professional starting-aid battery for daily
workshop use. This start aid device is cur-
rently the most powerful variant in the Re-
animator range. The integrated, extendible
handle and rollers even make the power
trolley suitable for mobile use on medium-
duty agricultural and construction machines.
Maintenance-free special batteries
On/Off switch prevents short-circuits
With acoustic warning for reverse polarity
With surge protection
With circuit breaker and fuse
High-performance clamps with earth
strap and brass jaws
With an automatic high-frequency
charger which is suitable for permanent
connection
1.3 Technical data
Rated voltage:
12/24 V
Peak current:
6200/3100 A
Inrush current:
3100/1170 A
Battery:
AGM battery
Battery capacity:
50 Ah
Cable length:
1.7 m
Cable cross-section:
50 mm²
Weight:
35.7 kg
Digital charge-level indicator
20 A circuit breaker
500 A fuse
CE-verified
2. Safety-related information
Read all the instructions carefully before us-
ing this product for the first time.
WARNING
Attention!
Increased risk of explosion!
Take the utmost care when selecting
voltages. Always ensure that the voltage
setting is correct. Within a very short
time, an incorrect voltage setting will
cause the internal batteries to emit gas
and thereby cause explosive gas to
accumulate.
Always observe the general accident
prevention regulations and wear appro-
priate personal protective equipment,
including safety goggles and protective
gloves.
The Reanimator and the charger are not
intended for use by children. People with
restricted physical, sensory or mental
capabilities, or who have insufficient ex-
perience and specialist knowledge, must
be supervised by a person responsible
for their safety whilst using the product.
Do not touch the inside of the device
with your fingers or hands.
Do not expose the Reanimator or the
charger to rain or snow.
Only use accessories which are appro-
ved by the manufacturer.
Do not use the Reanimator or the char-
ger if the output cable is damaged.
Do not use the Reanimator or the char-
ger if they have been subjected to a hard
impact, been dropped or been damaged
in any other way.
Do not dismantle the Reanimator or
the charger.
Working in the vicinity of lead-acid bat-
teries is dangerous. Batteries generate
explosive gases during normal operation
and while charging. Always ensure ade-
quate ventilation and avoid naked flames
and sparks for this reason. Naturally, this
also applies to smoking.
Ensure that the Reanimator and the
charger are placed on a dry, non-flam-
mable surface.
In order to minimise the risk of a battery
explosion, follow these instructions in
addition to those published by the bat-
tery manufacturer and the instructions
from the manufacturers of devices which
are intended for use in the vicinity of the
battery. Observe the safety notices on
these products and on the engine.
Attention:
Do not use the Reanimator
with batteries which cannot be recharged.
Only use the Reanimator with recharge-
able lead-acid batteries. Do not use with
dry cell batteries, such as those often
used in household appliances. Such
batteries can burst and thereby cause
physical injury or material damage.
Remove all personal effects made from
metal, such as rings, bracelets, necklaces
and wristwatches, when working with a
lead-acid battery. A lead-acid battery can
generate a short circuit that is suffici-
ently powerful to weld a ring or similar
metallic object, which can cause serious
burn injuries.
Exercise particular caution to prevent
metallic objects from falling onto the bat-
tery. These can cause sparks or short the
battery or other electrical components
and trigger an explosion.
To prevent sparks, ensure that the clamps
NEVER touch each other or come into
contact with the same metallic object.
3. Start-up
Inspect the device and the cables for visible
damage. The device’s housing must not ex-
hibit any cracks or other types of damage.
The insulation of the cables and the battery
charger pliers must be intact.
WARNING
Attention!
The device must be charged before
and after every use.
Wherever possible, leave the Reanimator con-
nected to the charger when not in use. This
will considerably prolong the battery life.
Press the button for the charge-level indica-
tor to monitor the battery’s charge-level.
Operating Instruction
95980803
Operating Instruction
95980803
11
www.herthundbuss.com 10
EN
EN