![HEROSE 01312 Operating Instructions Manual Download Page 27](http://html.mh-extra.com/html/herose/01312/01312_operating-instructions-manual_2126783027.webp)
Operating instructions
herose.com
21
5
Assembly
5.1
Installation position
With regard to the installation position, pay attention to the arrow showing the flow direction. When
installing the angle valve in a horizontal pipeline, a vertical position of the stem is recommended
(handwheel at the top) or an inclination of up to 65° from the vertical.
5.2
Notices regarding the mounting
Use suitable tools.
Allen keys of sizes 6, 8 and 10;
Open-ended spanners;
Torque wrench;
TIG welding machine;
Oxy-fuel welding machine;
Clean tools before the mounting.
Use suitable transport and lifting equipment for the mounting.
Open the packaging only directly before the mounting. Free from oil and grease for oxygen (O
2
)
Angle valves for oxygen are permanently labelled with “O
2
”.
Only install the angle valve if the maximum operating pressure and operating conditions of the
plant correspond to the marking on the valve.
Remove protective caps or covers before mounting.
Check the angle valve for dirt and damage.
DO NOT install a damaged or dirty angle valve.
Avoid damaging the connections.
The sealing surfaces must remain clean and intact.
Seal the angle valve with suitable seals.
No sealant (sealing tape, liquid sealing tape) may enter the angle valves.
Respect the suitability for use with O
2
.
Connect pipelines in a force-free and torque-free manner.
Stress-free mounting.
In order to ensure trouble-free operation, no impermissible static, thermal or dynamic stresses
may be transmitted to the angle valve. Observe reaction forces.
Temperature-dependent changes in length in the pipework system must be compensated with
expansion joints.
The angle valve is supported by the pipework system.
Detailed installation instructions are included for angle valves with pneumatic or electric actuator-
unit.
Driven angle valves: Mounting/dismounting the bonnet in the centre position of the actuator.
The angle valve must be protected against dirt and damage during construction work.
Remove any transport locks such as blocking bushing (optional).
Check the leak-tightness.
Summary of Contents for 01312
Page 2: ......
Page 6: ......
Page 20: ...Betriebsanleitung 14 Telefon 49 4531 509 0 ...
Page 34: ...Operating instructions 28 Phone 49 4531 509 0 ...
Page 48: ...Instrucciones de servicio 42 Teléfono 49 4531 509 0 ...
Page 62: ...Notice d utilisation 56 Téléphone 49 4531 509 0 ...
Page 76: ...Руководство по эксплуатации 70 Телефон 49 4531 509 0 ...
Page 85: ...操作指南 herose com 79 焊接 钎焊之后 插入新的密封圈 组装阀盖 切勿损坏密封圈 装上螺钉 以十字交叉方式将螺钉拧紧至规定的 紧固扭矩 旋转方向 顺时针 ...
Page 90: ...HEROSE GMBH ARMATUREN UND METALLE IV Phone 49 4531 509 0 Notizen Note Apunte Note заме тка 杂记 ...
Page 91: ...HEROSE GMBH ARMATUREN UND METALLE herose com V Notizen Note Apunte Note заме тка 杂记 ...