Operating instructions
4
Phone +49 4531 509-0
3
Transport and storage
3.1
Inspection of condition on delivery
Inspect the globe valve for damage upon receipt.
In case of transport damage, determine and document the precise extent of the damage, and
report it immediately to the supplying dealer/carrier and the insurer.
3.2
Transportation
Transport the globe valve in the packaging supplied.
The globe valve is delivered ready to operate with body ends protected by cover caps.
Protect the globe valve against hammering, impacts, vibrations and dirt.
Adhere to a transport temperature range of -20 °C to +65 °C.
3.3
Storage
Store the globe valve in a clean and dry place.
Make use of a desiccant or heating in damp storerooms to prevent the formation of
condensation.
Adhere to a storage temperature range of -20 °C to +65 °C.
4
Description of the globe valve
Refer to the respective catalogue page for further detailed information.
4.1
Structure
Design
Non-automatically opening and closing, straight-type globe valve.
Component
Design
Body
Straight-type
Bonnet
Flanged, internal spindle thread
Flanged, without spindle thread
Operating mechanism
Rising stem
Obturator
Disc with seal made of non-metallic materials
Stem bushing
Non self-sealing, packing gland
Body end
with soldering end
with welding end
with threaded end (G; R; NPT)
with flange connection
with welded-in/soldered-in pipes
4.2
Marking
The globe valves are provided with an individual marking for identification.
Symbol
Explanation
DN…..
Nominal size
PN…..
Rated working pressure (max. permissible operating
pressure)
-…..°C +…..°C
Temperature, min. / max.
Manufacturer's mark “HEROSE”
01/18
Year of construction MM/YY
12345
Type
01234567
Serial no.
EN1626
Standard
0045
CE-mark and number of the notified body
0045
PI-mark and number of the notified body
e.g. CF8 / 1.4308
Material