Operating instructions
herose.com
5
4.3
Intended use
Globe valves are used for shutting off and/or throttling media.
Install globe valves so that the stem is vertical and the type of
the medium enters under the cone.
The globe valves are opened or closed by turning the
handwheel or actuating the actuator.
NOTICE!
Tools for increasing handwheel torque are not
allowed.
Detailed instructions for installing the actuator are included for
globe valves with actuators.
4.4
Operational data
Globe
valve
Nominal
pressure
Permissible
operating
temperature
Recommended
operating
temperature
Max. operating
pressure
0131x
PN 50
-196 °C to +120 °C -
50 bar
0132x
0134x
PN 50
(DN150 = PN40;
DN200 = PN25)
-196 °C to +120 °C -
50 bar
(DN150 = 40 bar;
DN200 = 25 bar)
0164x
0241x
PN 50
-196 °C to +120 °C -
50 bar
0325x
0346x
PN 16
PN 40
Class 150
Class 300
-196 °C to +120 °C -
16 bar
40 bar
Class 150
Class 300
0333x
PN 40
Class 150
Class 300
-196 °C to +120 °C -60 °C to +120 °C
40 bar
Class 150
Class 300
0335x
0130x
PN 50
-196 °C to +120 °C -60 °C to +120 °C
50 bar
0133x
PN 50
(DN150 = PN40;
DN200 = PN25)
-196 °C to +120 °C -60 °C to +120 °C
50 bar
(DN150 = 40 bar;
DN200 = 25 bar)
0135x
0165x
PN 50
-196 °C to +120 °C -60 °C to +120 °C
50 bar
0240x
0125x
PN 50
-196 °C to +120 °C -
50 bar
0126x
0364x
PN 16
PN 40
Class 150
Class 300
-196 °C to +120 °C -
16 bar
40 bar
Class 150
Class 300
1114
PN 50
-196 °C to +120 °C -60 °C to +120 °C
50 bar
1116
1116F
0365x
PN 40
Class 150
Class 300
-196 °C to +120 °C -60 °C to +120 °C
40 bar
Class 150
Class 300
0127x
PN 50
-255 °C to +120 °C -
50 bar
0128x
0174x
PN 50
(DN150 = PN40;
DN200 = PN25)
-255 °C to +120 °C -
50 bar
(DN150 = 40 bar;
DN200 = 25 bar)
0184x
Close
Open