23
Type
No.
Description
Range
Unit of
meas-
urement
Step
Default
DOMESTiC HOT waTER - HEaTiNg
PaR
10
Boiler antifreeze threshold
0 .. +10
°C
1
3
PaR
11
external sensor antifreeze threshold
-9 .. +5
-- = disabled
°C
1
-2
PaR
12
Heating Curve Incline
0 .. 80
-
1
20
PaR
13
minimum Heating temperature adjustment
20 .. Par ts 1.4
°C
1
20
PaR
14
maximum Heating temperature adjustment
Par ts 1.3 .. 80
°C
1
80
PaR
16
Heating Post-Circulation time
0 .. 99
seconds
x 10
1
3
PaR
17
Heating Pump activation delay
0 .. 60
seconds
x 10
1
1
PaR
18
Re-ignition delay
0 .. 60
min
1
3
PaR
19
domestic Hot Water modulation with Flow meter
-- = disabled
1 = enabled
-
-
1
PaR
26
Zone Valve / Pump Relaunch delay
0 .. 99
min
1
0
PaR
29
anti-legionella Function (only hot water tank)
-- = disabled
50 .. 80
-
1
--
PaR
35
digital / analogue Pressure switch
0 = water pressure switch
1 = water pressure transducer
2 = water pressure transducer (only pressure displayed)
0 .. 2
-
1
1
PaR
40
modulating Pump speed
-- = no modulation
au = automatic 30
.. 100
%
10
au
PaR
41
∆t modulating pump delivery/Return
10 .. 40
%
1
20
PaR
47
system pump forcing (only in winter mode)
0 = disabled
1 = enabled
-
-
0
RESET
PaR
48
Inst Parameter set to default
-- ; 1
-
-
-
In the event of a fault/malfunction the message “aLL” will ap-
pear on the display with the alarm number eg. “aLL 04” (do-
mestic Hot Water sensor Fault).
Before repairing the fault:
– disconnect the appliance from the mains power by setting
the main switch to "oFF"
OFF
Fig. 32
– as a precautionary measure, close the gas isolation valve.
Repair the fault and start-up the boiler again.
Nb:
after having repaired the fault, when the alarm number
appears on the display together with the message
d
(see figure) press the button
y
to start the appliance up
again.
3.5
Fault / malfunction codes
Type
No.
Description
all
02
low water pressure in system
all
04
domestic hot water sensor fault
all
05
delivery sensor fault
all
06
no flame detection
all
07
sensor or safety thermostat intervenes
all
08
Fault in the flame detection circuit
all
09
no water circulating in the system
all
11
Gas valve modulator disconnected
all
12
Incorrect configuration of the open /sealed cham-
ber
all
15
Fan check cable disconnected
all
17
Fault regarding maximum deviation between the 2
ntC heating sensors
all
28
maximum number of consecutive releases
all
37
Fault due to low network voltage
all
40
Incorrect network frequency detected
all
41
Flame loss more than 6 consecutive times
all
42
Button fault
all
74
Fault in the 2nd element of the delivery sensor
all
81
Block due combustion during start-up
all
83
Irregular combustion (temporary error)
all
96
Block due to clogging in smoke outlet