S
AFETY
I
NSPECTION
35
12.1
Regular safety check
(In accordance with §10 ( 2 ) German Health and Safety regulations !)
Device type
Serial number
Inspection result
Start-up not permitted, verification required
Start-up possible, faults to be rectified by: ...............................................
No fault, start-up possible immediately
Safety inspection performed on:
……………………………………................................................
Name and address of qualified personnel
............................................................................................
…………………………………………
………………………………………..
Signature of competent person
Signature of operator
With the required rectification of faults
…………………………………………
………………………………………..
Signature of competent person
Signature of operator
Inspection step
OK
No
t O
K
re
-
ex
amin
ati
on
Remark
Nameplate
Sign with lifting capacity
Sign with bar mains pressure
Operating instructions (abbreviated)
Designation lift - lower
Secure fit of all supporting screws
Safeguard of the scissor pins
condition of the pneumatic lines
safety valve set to 3.5 bar operating pressure
Pressure gauge bar mains pressure P
max
= 8 bar
Control lever returns automatically to the '0' position when
released
Safety catch function
Loading ramps function
Interim drive over ramp function (
only HLS1200-61
)
Roll-off protection function
Protective flaps function (
only HLS1200-64
)
Function CE-Stop (only HLS1200-66)
Condition of the air bags
Condition of the supporting structure
Condition grounding line
(only HLS1200-64-66)
Functionality of the service lift with vehicle
Summary of Contents for K1200-HLS-61
Page 2: ...2 ...
Page 42: ...ADDITIONAL INFORMATION 42 Dimensions installation pit HLS1200 64 66 ...
Page 43: ...ADDITIONAL INFORMATION 43 Dimensions substructure HLS1200 64 66 ...
Page 44: ...ADDITIONAL INFORMATION 44 Schematic diagram installation HLS1200 64 66 ...
Page 45: ...ADDITIONAL INFORMATION 45 Dimension sheet HLS 1200 61 ...
Page 46: ...ADDITIONAL INFORMATION 46 Dimension sheet HLS 1200 64 66 ...