product.
• Periodically inspect the chimney and clean
whenever necessary. Also inspect the state of joints, glass, screws...
• Protect your hands with a glove or other insulating material because, during
operation, the opening and closing handle will be hot.
OUTSIDE AIR CONNECTION
• When installing the stove using the outside air connection, we recommend that the installation is
performed by qualified personnel.
• Always keep in mind that air is entering the stove through the connector. This air inlet can never
be blocked. Ensure that the pipe connecting the stove to the outside cannot be crushed and that
the entrance to the pipe cannot be blocked on the outside. It is
necessary to cover the inlet with a protective grill.
• The location of the outside air inlet of air must be protected
from
the wind to avoid a possible positive or negative pressure from affecting the combustion of the stove.
• Refer to the technical specifications at the end of this manual for the minimum diameter and the
maximum length of the pipe to be connected.
8
– STROUBLE SHOOTING
1.
Fire Will Not Burn - check
a)
the air inlet is not obstructed in any way,
b)
that chimney and flue ways are clear,
c)
that a suitable fuel is being used,
d)
that there is an adequate air supply into the room,
e)
that an extractor fan is not fitted in the same room as the fire.
2.
Fire Blazing Out Of Control - check
a)
the doors are tightly closed,
b)
the air controls are turned down to the minimum setting,
c)
the flue damper is closed ( if fitted),
d)
a suitable fuel is being used,
e)
the door seals are in good condition.
f) the chimney draft may be too strong
3) Soot forms on the window
a)
The firewood may be too wet
b)
the intake of secondary air may be insufficient
c)
fire not hot enough
4) The stove fails to heat fully
a)
The firewood may be too wet
b)
the intake of secondary air may be insufficient
5) Smoke or odour
a)
Weak chimney draft
b)
check for blockages in the flue pipe/chimney
c)
check the height of the chimney relative to the surroundings
6) Soot in the chimney
a)
The firewood may be too wet
b)
intake of secondary air may be insufficient
FIG. 6 - DISTANCIAS DE SEGURIDAD