background image

16 of 20

MOD. HIERRO FUNDIDO-GHISA-CAST IRON-FONTE-FERRO

10 - PIEZAS DE REPUESTO - RICAMBI - SPARE PARTS - RECHANGES – SOBRESSALENTES

CÓDIGO

NOMBRE

E30 S HF

E30 M HF

E30 MT HF

E30 L HF

1

9920164

9920165

9920489

9920166

ENCIMERA

2

9920167

9920168

9920168

9920169

VARILLA AMARRE ESTUFA

3

9920170

9920171

9920171

9920172

COSTADO IZQUIERDO

4

9920680

9920681

9920681

9920682

PLACA DEFLECTOR HIERRO FUNDIDO

5

9920674

9920655

9920655

9920675

COSTADO INTERIOR IZDO

6

9920179

9920180

9920180

9920181

CONJUNTO FIBRA DE VIDRIO

7

9920182

9920182

9920182

9920182

PARRILLA

8

9920183

9920184

9920184

9920185

COLECTOR PRIMARIO

9

9920186

9920187

9920187

9920188

FRENTE

10

9920189

9920190

9920190

9920191

CONJUNTO CRISTAL

11

9920192

9920192

9920192

9920192

TRENZA FIBRA CERAMICA 1/4" (3 m)

12

9920193

9920193

9920193

9920193

TRENZA FIBRA CERAMICA 3/8" (3 m)

13

9920194

9920195

9920195

9920196

CONJUNTO PUERTA HOGAR

14

9920197

9920197

9920197

9920197

CONJUNTO BISAGRA PUERTA HOGAR

15

9920198

9920199

9920199

9920200

ANGULAR REFUERZO DEFLECTOR

15

9920683

9920683

9920683

9920683

SUFRIDERA DEFLECTOR

16

9920656

9920656

9920656

9920656

CONJ. MANDO CIERRE PUERTA HOGAR

17

9920057

9920057

9920057

9920057

EJE CIERRE PUERTA HOGAR

18

9920447

9920445

9920445

9920448

CONJUNTO CENICERO

19

9920203

9920204

9920204

9920205

FONDO

20

9920206

9920206

9920206

9920206

MANDO VALVULA ENCENDIDO

21

9920207

9920207

9920207

9920207

MANDO VALVULA CRISTAL

22

9920208

9920208

9920208

9920208

TUBO VALVULA ENCENDIDO

23

9920446

9920446

9920446

9920446

CUERPO CAJON PARA CENICERO

24

9920211

9920212

9920212

9920213

COSTADO DERECHO

25

9920678

9920657

9920657

9920679

TRASERA INTERIOR

26

9920223

9920224

9920490

9920225

TRASERA

27

9920676

9920658

9920658

9920677

COSTADO INTERIOR DCHO

Summary of Contents for E-30 Series

Page 1: ...1 of 20 E 30 INSTALLATION USE AND MAINTENANCE INSTRUCTIONS 7100AA130_5 03 2021 ...

Page 2: ...rior warning Industrias Hergóm S A domiciled in Soto de la Marina Cantabria Spain offers a TWO YEAR warranty on its products The geographical coverage of the said warranty only includes the countries in which Industrias Hergom SA a subsidiary company or an official importer distribute its products and where Community Direc ve 1999 44 CE is in force The warranty comes into force on the purchase dat...

Page 3: ...e alarm manufacturer s instruc ons Provision of an alarm must not be considered a subs tute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system Stove paint Aerosols Paint aerosols are flammable and therefore dangerous to use around a lit stove Be sure to allow aerosols spray paints to dry and ven late the room well before ...

Page 4: ...L M and S to meet each users heating requirements Made of cast iron with parts that are assembled sealed and screwed together Cast iron or Vermiculite lined By model They are designed for use with firewood only They can burn pieces of wood up to 40 50 or 60 cm in length depending on the model See the table on page 12 Ligh ng up valve Primary air adjustment valve Self cleaning glass Hinged front do...

Page 5: ...he handle gently down to the closed posi on Fig 3 Ligh ng up valve Fully open the valve when ligh ng the stove Fig 3 Adjustment Glass Cleaning Valve Fully open the glass pane cleaning air valve when ligh ng the stove Once an ideal combustion rate has been achieved adjust the vale to prevent excessive air intake which will cause excessive combustion levels and temperatures The intermediate position...

Page 6: ...lighting it up slowly Overheating Overheating means that you have operated your heater at a excessively high temperatures for a long period of me This can damage your appliance and therefore it is a situa on that must be avoided Overheating is the result of excessive draw due to any of the following reasons The Primary Air Valve is excessively open for the type of wood being used The chimney is to...

Page 7: ...apter in the Manual for Installers that refers to this topic DOOR PANES Cleaning Fireplace window cleaning liquids are quite effec ve products Never try to clean the glass while the fireplace is working We recommend using HERGOM window cleaning products for their proven efficacy If the glass pane on the fireplace door is constantly covered in soot this means your fire is poor and that the connec n...

Page 8: ...at a distance from the fireplace Never use coal or fuels that are not recommended for the operation of this product Periodically inspect the chimney and clean whenever necessary Also inspect the state of joints glass screws Protect your hands with a glove or other insulating material because during opera on the opening and closing handle will be hot OUTSIDE AIR CONNECTION When installing the stove...

Page 9: ... E 30 S E 30 M MT E 30 L A 280 310 310 325 B 380 440 440 520 C 740 785 785 810 D 700 740 740 770 E 120 120 140 F 210 225 225 225 G 420 470 470 540 H 490 545 545 615 I 590 660 660 750 J 150 150 150 200 K 605 L 150 162 162 162 ...

Page 10: ... 3 Accepts logs of the following length mm 400 500 600 Smoke collar Ø mm 150 150 200 Metal chimney Ø mm 150 150 200 Recommended chimney height m 5 6 5 6 5 6 Masonry chimney min approx mm 200x200 200x200 250x250 Recommended draw Pa 12 12 12 Smoke outlet Vertical Vertical Vertical Weight Kg 110 150 190 Outside air inlet Ø mm 80 80 80 Minimum diameter of the outside air inlet pipe Ø mm 80 80 80 Maxim...

Page 11: ...or use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England appliances are exempted by publica on on a list by the Secretary of State in accordance with changes made to sec ons 20 and 21 of the Clean Air Act 1993 by sec on 15 of the Deregula on Act 2015 In Scotland appliances are exempted by publi...

Page 12: ... a reasonable period If there are too few embers in the fire bed add suitable kindling to prevent excessive smoke Fuel Overloading The maximum amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Air controls doors le open Operation with the air controls fully open can cause excess smoke The appliance must not be operated with air controls or door le op...

Page 13: ...13 of 20 MOD VERMICULITA VERMICULITE 9 DESPIECE ESPLOSO EXPLODED VIEW EXPLOSÉ EXPLODIDO ...

Page 14: ...920192 9920192 9920192 9920192 TRENZA FIBRA CERAMICA 1 4 3 m 12 9920193 9920193 9920193 9920193 TRENZA FIBRA CERAMICA 3 8 3 m 13 9920194 9920195 9920195 9920196 CONJUNTO PUERTA HOGAR 14 9920197 9920197 9920197 9920197 CONJUNTO BISAGRA PUERTA HOGAR 15 9920198 9920199 9920199 9920200 ANGULAR REFUERZO DEFLECTOR 16 9920201 9920201 9920201 9920201 CONJ MANDO CIERRE PUERTA HOGAR 17 9920057 9920057 99200...

Page 15: ...15 of 20 MOD HIERRO FUNDIDO GUISA CAST IRON FONTE FERRO 9 DESPIECE ESPLOSO EXPLODED VIEW EXPLOSÉ EXPLODIDO ...

Page 16: ...12 9920193 9920193 9920193 9920193 TRENZA FIBRA CERAMICA 3 8 3 m 13 9920194 9920195 9920195 9920196 CONJUNTO PUERTA HOGAR 14 9920197 9920197 9920197 9920197 CONJUNTO BISAGRA PUERTA HOGAR 15 9920198 9920199 9920199 9920200 ANGULAR REFUERZO DEFLECTOR 15 9920683 9920683 9920683 9920683 SUFRIDERA DEFLECTOR 16 9920656 9920656 9920656 9920656 CONJ MANDO CIERRE PUERTA HOGAR 17 9920057 9920057 9920057 992...

Page 17: ...al similarity of the three stoves sizes please find enclosed the list of spare parts for both based on the exploded view of the E 30 M displayed on the previous pages We recommend using spare parts recommended by the manufacturer ...

Page 18: ...eserves the right to alter its products without prior warning Any liability due to manufacturing defects will be subject to the criteria and verification of the company s experts and will be limited to the repair or replacement of its products excluding any construction work or damage the said repairs may cause ...

Page 19: ...19 of 20 ...

Page 20: ...AA130_5 03 2021 Tel 0034 942 587 000 E mail hergom hergom com www hergom com Distributed in the United Kingdom by Eurostove Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Telephone 01934 750500 technical eurostove co uk www eurostove co uk CODE H90702 49 00 99 00 ...

Reviews: