User manual // Speed Max
HENSEL-VISIT GmbH & Co. KG
27
Should these react to a fault condition the flash unit will
switch off. Only an authorized Hensel service station is
able to first analyze and then eliminate the fault.
If the modeling light fuse has to be replaced make first
sure that the flash unit is switched off, and the mains plug
is pulled in order to separate the unit from the mains
supply.
The fuse holder
18
is located next to the mains socket on
the back of the unit. The removable insert can be pried up
using a small screw driver. The fuse located in the rear of
the drawer is the active one, and the one up front,
completely recessed in its storage compartment, is the
spare one!
Replacement of modeling lamp
Replace a modeling lamp only when the unit is switched
off and unplugged from the mains outlet. Use halogen
modeling lamps
300W
maximum
(base G 6.35)
. Make
sure that the modeling light circuit is protected by a fuse
with the correct rating and specifications. In any case, the
fuse must always be checked, because it is most likely to
blow when the halogen lamp goes out.
Wait until the glass protection dome and the modeling
lamp have cooled down sufficiently. Remove the glass
dome carefully (specific instructions on previous pages)
and pull the expended halogen lamp from its socket and
replace it with a new one.
It must be prevented, by all means, to touch the flash tube
and halogen lamp directly (danger!)
Handle the halogen lamp carefully. Avoid touching the
quartz glass envelope of the halogen lamp with your
fingers, because that may result in corrosion due to the
skin oils and acids burning-in, increasing the danger of a
bursting glass envelope during operation. It is best to use
protective cotton gloves or a clean cloth when handling it.
Max. 300W
Halogen
18