User manual // Speed Max
HENSEL-VISIT GmbH & Co. KG
19
and ENERGY
3
now list the number of flashes selected
last as a four-digit number (0002 to 1000).
Examples of readings on displays FLASH/s and ENERGY:
Number of
flashes
Display FLASH/s
Display
ENERGY
3
00
03
50
00
50
400
04
00
Briefly press the multifunctional control
4
to change the
number of flashes. The lowest digit of the four-digit value
starts blinking. Turning the multifunctional control lets you
select the desired number. Changing to the next higher
digit is done by using the multifunctional control again.
The input process is completed when the last digit has
been changed and the control is pressed, or automatically
when the control has not been used in more than four
seconds. The pre-selected number of flashes can now be
triggered via the synch input and is not depending on the
length of the synch impulse.
Pressing the FC button
13
again for 1.5 s deactivates the
flash sequence mode, as does switching off the unit with
the mains switch
16
.
In this mode, there is another function to select the flash
repeat times.
To use this function, you have to first deactivate the flash
sequence mode (see above). By pressing the ID
6
button,
the display changes from “FS” to “FI” (flash interval). The
displays FLASH/s
2
and ENERGY
3
show the last
selected time in milliseconds displayed as a four-digit
number (up to 9999 milliseconds = 10 seconds).
Because the flash energy is kept constant, there is a
minimal flash repeat time for each energy level which is
listed in a table stored in the unit. If the last value selected
is smaller than the value of the minimum possible flash
repeat time, the value listed in this table will be selected
automatically. Depending on the power level, this value
cannot be fallen short of. Four seconds after its last use,
the menu is exited and the display changes from “FI” to
“FS”.
4:
13:
FC
16:
ON/OFF
6:
ID
2, 3: