User manual Integra Mini 300
19
HENSEL-VISIT International GmbH
9 Maintenance
ATTENTION!
The device must be disconnected from any power supply before
attempting any maintenance procedure.
The compact flash unit
Integra Mini 300
does not require
much maintenance.
The outside of the unit must be regularly cleaned of dust and
dirt to guarantee the electrical safety of the device.
Note:
Only clean the unit with a dry cloth!
Regular maintenance intervals
National safety regulations require the maintenance and ins-
pection of any electric device and equipment in regular inter-
vals. Compact flash units, generators, and accessories must
be inspected in regular intervals to ensure safe operation. An
annual inspection of such devices ensures safe operation and
retains equipment value.
Replacing the fuses
ATTENTION!
Fuses must not be „patched up“ or otherwise bypassed. Only
use spare fuses that meet the below listed requirements and
have a fast response rating.
The compact flash unit must be disconnected from any power
supply before replacing a fuse.
Safety fuses for use with 300W halogen lamps: F 4 A H.
Only use fuses with a high switch-off capacity, labelling „H“,
according to EN 60127-2/1 or IEC 127-2/1. A wrong fuse can
increased the danger of the halogen lamp bursting and the
glow filament can burn out.