Model
690
2-26
2-28. IGNITION MODULES
Sends 24 volts to the ignitors and gas control valve.
LED Indication
3 different modules are in the field. The White Rogers and
Fenwall modules have a red LED, and the Robertshaw modules
have a green LED. These LEDs help to identify a failure.
For White Rogers & Fenwall modules, when the control calls
for heat, the
LED flashes, then goes out, indicating control is
functional. If the LED continues to flash, the module did not
sense a pilot flame. If LED stays on continuously, an internal
fault has been detected, and the module should be replaced.
Robertshaw
For Robertshaw, when the control calls for heat, the LED will
be on continuously, indicating the control is functional. If LED
flashes, module did not sense a pilot flame. If LED goes out
while the control is calling for heat, an internal fault has been
Replacement
detected, and the module should be replaced.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel as discussed in section 2-7.
3. Remove the condensation drain pan.
4. Using a Phillips head screwdriver, remove the screws
securing the module cover and remove the cover.
5. Label and remove the wires from the module.
6. Using a 3/8” socket and Phillips head screwdriver, remove
nuts and screws securing module and remove it from unit.
7. Replace with module in reverse order.
White Rogers
Fenwall
LED
LED
Sept. 2007
Summary of Contents for PFG-690
Page 1: ...Henny Penny Pressure Fryer Model PFG 690 TECHNICAL MANUAL...
Page 2: ......
Page 49: ...Model 690 2 31 AP0803002 below June 2008...
Page 50: ...Model 690 2 32 AP0803003 above June 2008...
Page 51: ...Model 690 2 33 June 2008...
Page 52: ...Model 690 2 34 AP0803003 above June 2008...
Page 53: ...Model 690 2 35 AP0803002 below June 2008...
Page 54: ...Model 690 2 36 AP0803003 above Aug 2006...
Page 55: ...Model 690 2 37 AP0803002 below June 2008...
Page 56: ...Model 690 2 38 AP0803003 above Aug 2006...
Page 57: ...Model 690 2 39 100 120 Volt FAST Wiring Diagram AP0803002 below June 2008...
Page 58: ...Model 690 2 40 AP0803003 above June 2008...
Page 59: ...Model 690 2 41 230 Volt FAST Wiring Diagram AP0803002 below June 2008...
Page 60: ...Model 690 2 42 AP0803003 above June 2008...
Page 61: ...Model 690 2 43 220 240 Volt FAST Wiring Diagram AP0803002 below June 2008...
Page 62: ...Model 690 2 44 AP0803003 above June 2008...
Page 64: ...Model 690...
Page 66: ...Model 690 3 2 FIGURE 3 0 FRAME COVER ASSEMBLY Oct 2002...
Page 72: ...Model 690 3 8 FIGURE 3 4 LID COVER ASSEMBLY July 2007...
Page 74: ...Model 690 3 10 FIGURE 3 5 DRAIN PAN FILTER ASSEMBLY Aug 2010...
Page 76: ...Model 690 3 12 Figure 3 6 Filter Pump Assembly Below SN AP0401001 Aug 2010...
Page 78: ...Model 690 3 14 Figure 3 7 Filter Pump Assembly SN AP0401001 Above Sept 2005...
Page 80: ...Model 690 3 16 Figure 3 8 Gas Burner Assembly Oct 2012 2 2 2 1 1 3 4 5 6 7 8 9 10 11 12...
Page 82: ...Model 690 3 18 Figure 3 9 Gas Piping Controls April 2012...
Page 87: ...Model 690 3 23 3 13 Deadweight Solenoid Assembly SN AP082029 ABOVE Aug 2010...
Page 90: ...Model 690 3 26 Figure 3 14B STEAM Box hose Assembly SN AP0802028 BELOW Aug 2010...
Page 92: ...Model 690 3 28 Figure 3 15 Flue Assembly Blower SN AP0802028 BELOW July 2008...
Page 94: ...Model 690 3 30 Figure 3 16 Flue Assembly Blower SN AP0802029 ABOVE 6 Aug 2010...
Page 96: ...Model 690 3 32 Figure 3 17 Solenoid Valve Assembly Sept 2005...
Page 98: ...Model 690 3 34 Figure 3 18 Frypot Drain Piping Oct 2008...
Page 100: ...Model 690 3 36 Figure 3 19 Lift Beam Shrouds SN AP0802028 BELOW July 2008...
Page 102: ...Model 690 3 38 Figure 3 20 Counterweight Pulley System SN AP0802028 BELOW July 2008...
Page 105: ...Model 690 3 41 Figure 3 22 FAST Ready Parts Oct 2004...