2
7
July 2014
Recovery Information for each Vat
1.
Press and release
and REC shows in the left display and
the recovery time that oil temperature went from 250°F (121°C)
to 300°F (149°C) shows in the right display. For example,
REC 1:05
means it took 1 minute and 5 seconds for the
oil temperature to recover to 300°F (149°C) from 250°F (121°C).
Selected Languages
2.
Press and release
twice and primary language shows in the left
display and secondary language shows in the right display. Press
√
button under either language to switch unit operation to that lan-
guage
.
If no buttons are pressed within 5 seconds in any of stats modes, the controls
revert back to normal operation.
Cook Cycles Remaining before Filtering
1.
Press and release either
or
and the left display
shows “COOKS REMAIN” and the right display shows the
number of cook cycles before the next auto filter. For example,
REMA IN
3 6
means after 3 more
cook cycles on left vat, controls ask the operator if they are ready to
filter or not. But, 6 more cook cycles remain on the right vat.
Time and Date
2.
Press either
or
twice and the time-of-day and date of the
most recent filter activity shows in the displays.
Actual Oil Temperature
1.
Press
and the actual oil temperature shows in the display, for
each vat.
Set-point Temperature
2.
Press
twice and SP shows in the display, along with the set-
point (preset) temperature of each vat.
3-16.
INFO BUTTON
STATS
3-17.
FILTER BUTTON
STATS
3-18.
TEMP BUTTON
STATS