![Henny Penny EVOLUTION ELITE EEG-241 Technical Manual Download Page 36](http://html.mh-extra.com/html/henny-penny/evolution-elite-eeg-241/evolution-elite-eeg-241_technical-manual_2124332036.webp)
Model EEG-241, 242, 243, 244
34
Aug. 2014
5-4. TECH MODE (Continued)
Press ▼ button and “AIF REQ” and “RQ=Y OK=Y” shows in
the displays.
REQ=Y” means that this particular control is currently request-
ing control of the AIF Board outputs.
“OK=Y” means that the AIF Board has granted this control the
authority to control the AIF Board outputs.
Press ▼ button and “FILR IN” and “USE BY 1(ex)” shows in
the displays. These displays shows which controls are using the
filtering system.
“USE = 0” = not in use
“USE = 7” = used by AIF
“USE = 1 to 5” = used by control PCB
Press ▼ button and “CPU POSN” and “1 OF 3(ex)” shows in
the displays. These displays shows which controls are plugged
into which port on the AIF board.
For example, the left control should be plugged into port 1, and
on a 3 control fryer, shows “1 OF 3” on the display.
If the right control is unplugged, then the left control would show
“1 OF 2” instead of “1 OF 3”.
Press ▼ button and “INP E_P_” and “JL_Rx DF_” shows in
the displays.
Summary of Contents for EVOLUTION ELITE EEG-241
Page 2: ......