Model EEG-241, 242, 243, 244
10
Aug. 2014
SECTION 2. INFO & FILTER BUTTON STATS
2-1. INFO BUTTON STATS
Actual Oil Temperature
1. Press and the actual oil temperature shows in the
display, for each vat.
Set-point Temperature
1. Press twice and SP shows in the display, along with
the set-point (preset) temperature of each vat.
Recovery Information for each Vat
1. Press 3 times and REC shows in the left display and
the recovery time that oil temperature went from 250°F
(121°C) to 300°F (149°C) shows in the right display. For
example, means it took 5 minutes and
30 seconds for the oil temperature to recover to 300°F
(149°C) from 250°F (121°C).
Cook Cycles Remaining before Filtering
1. Press and release either button and the left display
shows “COOKSREMAINING” and the right display shows
the number of cook cycles before the next auto filter. For
example.
means after 3 more cook cycles on the left vat, the controls
asks the operator if they are ready to filter or not. But, 6
more cook cycles remain on the right vat.
Time and Date
2. Press either twice and ‘FILTERED” shows in the
diplays, along with the time-of-day and date of the last
filter.
Filter Pad Hours
3. Press either three times and ‘FLTR PAD XX HRS”
shows in the diplays.
REC 5:30
2-2. FILTER BUTTON STATS
REMA INING
3 6
If no buttons are pressed within 5 seconds in
any of stats modes, the controls revert back to
normal operation.