Installation – Gas Units 

(continued)

ELECTRICAL SUPPLY-CSG

The gas Combi-Steamer requires 120 volt, single phase, 60 Hertz, 15 amp, 3 wire grounded service.  The gas unit
is factory equipped with a grounded cord and plug.

NOTE: 

The unit will not function and the reset signal will stay on with the white wire connected to the live black wire

and the black connected to neutral.  An electrical schematic is located behind the left side panel of unit.  A separate
fused disconnect switch, or circuit breaker, must be installed for each unit.

GAS SUPPLY-CSG

The gas Combi-Steamer is factory available for either natural or propane gas.  Check the data plate to determine
the proper gas supply requirements.

DO NOT DISCONNECT THE GROUND PLUG.  This unit MUST be adequately and safely grounded or
electrical shock could result.  Refer to local electrical codes for correct grounding procedures or in
absence of local codes, with the National Electrical Code, ANSI Z223.1 latest edition and electrical code
ANSI/NFPA No. 70-1990 latest edition.  In Canada, all electrical connections are to be made in accordance
with the CAN/CGA B149.1 or .2 installation code and/or local code and the Canadian electrical code,
Part 1, CSA C22.1.

Before connecting incoming power to the unit, no more than 120 volts should show at each leg to ground.
Connecting a high leg to the black lead of the unit will severly damage many electrical components in the
unit and void all warranties.  Call your local electrician or electric power supply company.

DO NOT attempt to use any gas other than that specified on the data plate.  Conversion kits can be
installed by your distributor if required.  Incorrect gas supply could result in a fire or explosion resulting
in severe injuries and/or property damage.

To avoid possible serious personal injury, the installation must conform with local codes, or in the
absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1988 or latest edition.  In Canada,
CAN/CGA-B 149.1 Natural Gas Installation Code CAN/CGA-B 149.2 Propane Installation Code.

All Henny Penny Combi-Steamers are equipped with two heat exchanger systems.  One is responsible for steam
production, the second for convection heat.  Each individual heat exchanger is heated with a separate burner
assembly.

Summary of Contents for B-1020

Page 1: ...e Back Side CSB CSM CSL 6 10 1020 6 150mm 2 50mm 2 50mm NOTE 14 350mm is recommended at the left side of the unit for service purposes Place the combi steamer on an original Henny Penny stand or on a...

Page 2: ...shing oven racks into unit The oven rack must be positioned vertically in the unit not tilting For minor unevenness in floor the oven rack can be leveled using the optional leveling device If necessar...

Page 3: ...70 1990 NOTE All connections must comply with the oven data plate A separate fused disconnect switch or circuit breaker not furnished MUST be installed in the electrical supply line FOR EACH OVEN NOTE...

Page 4: ...or local plumbing codes The unit has an integrated vented drain system which acts as a reverse flow check valve so it may be connected directly with a P trap to the drain system Installation Electric...

Page 5: ...ill provide easy loading and unloading without interfering with the final assembly of food orders Installation Gas Units Do Not puncture the cabinet with any objects such as drills or screws as electr...

Page 6: ...version The stacked version kit comprises two different draft hoods one with a single outlet and the second with a double outlet A flue riser completes the stacked version flue assembly Fix the singl...

Page 7: ...n integrated vented drain system which acts as a reverse flow check valve so it may be connected directly with a P trap to the drain system Should the water pressure exceed 87 psi a pressure regulator...

Page 8: ...all electrical connections are to be made in accordance with the CAN CGA B149 1 or 2 installation code and or local code and the Canadian electrical code Part 1 CSA C22 1 Before connecting incoming p...

Page 9: ...reates double bends causing work fatigue failure of the fittings In all installations where self draining is not necessary connect metal hose in a vertical loop DO NOT CONNECT METAL HOSE HORIZONTALLY...

Page 10: ...nces in the kitchen are on high flame The mini mum and maximum incoming line flow pressures should be as follows Natural 7 11 water column Propane 11 water column Installation Gas Units continued Neve...

Page 11: ...be taken by installing a gas pressure gauge on the front of the unit s main gas valves test port This should be done with all gas appliances in operation on the same gas supply line Should the manifol...