7 of 10
Instruction handbook EQ HD14
Version 1.0 · 27.10.20
EN
8) TROUBLESHOOTING
No.
Fault
Cause
Remedy
1
Plunger discs cannot
enter the cartridge
• Cartridge not fully inserted in
cartridge holder
• Foreign matter in cartridge guide
• Wrong diameter of plunger discs
installed
• Check that the correct cartridge
holder is installed and is not
damaged. Push cartridge fully down
into the cartridge sleeve.
• Remove foreign matter from
cartridge guide (do not use sharp
tools).
• Check the correct diameter of
plunger discs. Change plunger
discs if necessary.
2
Cartridge cannot be
removed from dispenser
• Plunger discs are still in position
inside the cartridge
• Fully retract the plungers by using
the retract button (check dispense
volume indicator).
3
Dispensing is interrupted
• Compressed air supply has been
interrupted
• Check compressed air supply
pressure. Check connection to
dispenser.
4
Unable to discharge
material
• Material has cured in the mixer
• Pressure not high enough
• Replace the mixer. Refer to mixer-
open-time in technical data sheet of
materials to be dispensed.
• Gradually increase the pressure by
turning the pressure regulation
valve.
5
Leaking air noise
• Inlet pressure too high –
safety valve blowing off
• Leakage at compressed air
connection
• Leakage from handle
• Check and reduce inlet pressure to
adequate level.
• Check and tighten the adapter.
• If the source of air leakage is inside
the handle please send the device
to the manufacturer or authorized
service station for inspection.
6
Uneven dispensing speed
• Foreign matter in driving unit /
damaged sealing
• Send device to manufacturer
or authorized service station for
inspection (never use solvents to
clean the air path).
Summary of Contents for Loctite EQ HD14
Page 2: ...II 1 7 6 2 9 4 10 14 0 13 11 12 7 8 7 8 8 10 5 7 3 A B D E G H C I F A B a b a a...
Page 3: ...III X Y 1 1 2 1 4 1 4 1 X Y 1 1 2 1 10 1 10 1 EQ HD14 200mL EQ HD14 400mL J X Y...
Page 66: ...EQ HD14 1 0 27 10 20 3 10 ZH 10 7 11 A 4 10 7 CE CE A B C D...
Page 69: ...EQ HD14 1 0 27 10 20 6 10 ZH 8 1 2 3 4 5 6...
Page 71: ...EQ HD14 1 0 27 10 20 8 10 ZH 11 2 1 1 2 1 2 1 2 4 5 3 6 7 1 1000 kPa 2 680 kPa 3 4 5 6 7...
Page 72: ...EQ HD14 1 0 27 10 20 9 10 ZH 12 12 o 16...
Page 73: ...EQ HD14 1 0 27 10 20 10 10 ZH...