11
5.4 Parameter Setting Page
1.
Operating Mode selection: Continue, Timer or Advance
Continue Mode: The LED head will turn ON when a footswitch is pressed and remain ON
until the footswitch is released. The intensity can be set up for each channel independently.
Timer Mode
: The LED head will turn ON when a footswitch is pressed and remain ON for the
duration that is set on the timer. If the time is set to 0 then when a footswitch is pressed the
LED head will turn ON and remain ON until the Footswitch is pressed again. The intensity
can be set up for each channel independently.
Advance Mode: This enables intensity to change automatically during the curing cycle.
2.
Link Button: The linked LED head will turn on with start signal.