Sach-Nr. 2 732 017; Version 1310301WBI
7/28
function
code
alternatives/signification
basic settings
F0
0*
no function
1
all function codes are set to the default values (*-marked)
count mode
F1
Input A
Input B
Input C
0 *
count Input
gate
reset
1
count Input
direction(u/d)
4
reset
2
count Input
direction(u/d)
4
gate
3
adding
subtracting
reset
4
adding
subtracting
gate
5
adding
adding
reset
6
channel A
1
channel B
1
reset
7
channel A
1
channel B
1
gate
decimal point
F3
0*
no decimal point
(on display)
1
one decimal place (xxxxx.x)
2
two decimal places (xxxx.xx)
3
three decimal places (xxx.xxx)
reset/setmode
F4
0*
reset to „0“, no autoreset
1
reset to „0“, with autoreset when reaching preset 2
2+3
2
set to preset 2, no autoreset
2+3
3
set to preset 2, with autoreset when reaching „0“
2+3
signal time
F6
2
OFF
no Output signal
output 1
On
bistable Output signal (latching), will be deleted by Out 2
0,02
20 ms
0,05
50 ms
0,10*
100 ms
0,20
200 ms
0,50
500 ms
1,00
1 s
signal time
F7
2
see
see above; signal time output 1
output 2
above
Output with
F9
0*
Do not activate the main preset output (OUT 2)
3
in case of Reset
reset
1
Activate the main preset (OUT 2)
3
in case of reset
pnp/npn-
F10
0
npn with 8V level (negative)
selection
1*
pnp with 8V level (positive)
2
npn with TTL-level
3
pnp with TTL-level
input
F11
0
30 Hz attenuation (for contacts)
attentuation
1 *
no attentuation, 5 kHz (bidirectional counting: 2,5 kHz)
dyn./static
F12
0*
static reset
Reset
1
dynamic reset (counting possible during reseting)
output
F14
0*
after power fail, the signal times will not be restarted
signal memory
1
after power fail, the signal times will be restarted
additional
F15
0*
disabled
totalizer
1
enabled
keylock for
F20
0*
key reset is possible
reset key 6+4
1
key reset is not possible (or possible with delay see F29)
keylock F21
2
0*
access to preset 1 is possible
for preset 1
1
access to preset 1 is not possible (or delayed see F29)
keylock F22
2
0*
access to preset 2 is possible
for preset 2
1
access to preset 2 is not possible (or delayed see F29)
keylock
F23
0*
access to prescaler is possible
for prescaler
1
access to prescaler is not possible (or delayed see F29)
keylock mode
F29
0*
access to parameters from F20-F23 is possible after
(F20-F23)
holding the keys for more than 10 sec.
1
access to parameter is not possible
* default values
1
bidirectional counting with single evaluation (eg. for encoders with 2 channels A,B)
2
parameter only appears for preset version
3
with appliances with one preset only, this applies to preset 1 and output 1 (OUT 1)
4
Input B passive (0V at PNP or 24V at NPN or open)
Count direction positive
Input B active (24V at PNP or 0V at NPN)
Count direction negative
2.2
Programming of function codes
Programming mode:
press while
switching
Power on
Change parameter:
press
Return to count mode:
press
> 5 s e c
Change to the next function:
press