24/28
Sach-Nr. 2 732 017; Version 1310301WBI
7. Specifications
Counter,
Batch counter,
2-Shift counter
Tachometer
Time-counter
Display
LED or LCD, 6 digits, leading zero suppression, decimal
point
Digit height
LED 7,6 mm; LCD 9 mm
Supply voltage
12...24 VDC or 24 VAC; 100 VAC; 115 VAC; 230 VAC; 50/60 Hz
Tolerances
±10%
Current consumption
12...24 VDC < 150 mA
24 VAC < 250 mA; including sensor supply
100/115/230 VAC < 50 mA; including sensor supply
Overload protection
ext. fuse DC: 0,16 AT/IEC 127; DC: 0,2 AT/UL 198
24 VAC: 315 mAT
230 VAC: 32 mAT; 115/100 VAC: 63 mAT
Sensor supply
only when AC operated: 12...30 VDC, max 50 mA
Data retention
non-volatile memory > 10 years
Electrical connection
screw terminals
Mounting
with clamping frame, panel thickness max. 11mm
Amplitude thresholds
< 2 V and > 8 V or < 2 V and > 3.8 V with TTL-Level, max 40 VDC
Active edge
programmable; positive with pnp input; negative with
npn input
Pulse shape
any (squarewave 1:1 for max. frequency)
Input resistance
approx. 10 kOhm (static)
Counting frequency
max. 5 kHz (2.5 kHz bi-directional); with the accessory totalizer
switched on, the count frequency is diminished by approx. 10%
Prescaler
Multiplier programmable from 0,001 to 999,999
Count inputs A, B
- phase discriminator with single evaluation
- differential mode (add/sub)
- count direction mode
- totalizing mode (add/add)
Pulse length min.
17 ms (30 Hz), 100 µs (5 kHz)
Control Input C
- manual reset possible
- external reset, static or dynamic, programmable,
pulse length > 5 ms
- automatic reset when main preset has been reached
(programmable)
Relay
changeover contact max. 250 VAC / 30 VDC, min. 5 V AC/DC
max. 1 A, min. 10 mA, delay < 5 ms
Transistor
pnp output 12...24 VDC; max 10 mA with DC supply
pnp output
12...30 VDC; max 10 mA with AC supply
Count mode
period measurement
Response time
Display and outputs are checked every 500 ms (f>2 Hz);
If f<2 Hz, there is an update at the end of each period
Alarms
2 alarms with programmable start-up-suppression
Time bases
programmable; sec, min., h
or in display format HH:MM:SS
Resolution
programmable 1; 0,1; 0,01; 0,001
Function
single pulse measurement (short time meter) or
cummulated counting (hour meter)
count mode
pulse width or period measurement (start-stop)
Operating Temperature
0°C ... 50 °C
Storage Temperature
- 20 °C ... + 60°C
Protection Class
front side IP 65 (EN 60529)
Vibrostability
10 m/s
2
(10...150 Hz) according to IEC 68-part 2-6
Shock stability
100 m/s
2
(18 ms) according to IEC 68- part 2-27
General Rating
according VDE 0411, DIN 57411, EN 61010, protection class II
Climatic Standards
DIN 40 040: 40/92 °C/% relative air humidity; KWF
Contamination level
2, according to VDE 0110
EMC-Noise immunity
EN 50082-2
EMC-Emission
EN 50081-2
Ambient Conditions /
Safety Regulations