background image

10.

11.

| Original User Manual | Item number 130-300-000 I Subject to change

| Original User Manual | Item number 130-300-000 I Subject to change

EN

EN

Responsibilities of the operator (in commercial use)

The operator of the appliance is required to fulfill their obligations under health and safety laws. Aside 
from the safety instructions given in this manual, all regulations on safety, accident prevention and 
environmental protection applicable to the place of operation must be observed. 

The operator is required to become familiar with all applicable health and safety regulations and 
establish by means of a risk assessment any additional hazards that arise from the specific working 
conditions present in the appliance’s place of operation. The operator must incorporate the findings of 
this risk assessment into instructions on how to operate the appliance.

The operator is required throughout the service life of the appliance to verify that the operating 
instructions they created comply with the latest revision of all applicable rules and standards and revise 
them if necessary.

The operator is required to clearly assign and define the responsibilities for installation, operation, 
maintenance and cleaning and ensure that all employees handling the appliance have read and 
understood the manual. The operator must furthermore train their staff and inform them about the 
hazards involved at regular intervals.

The operator must authorize the operating personnel to reject instructions from third parties which 
breach safety regulations.

The operator must provide the personnel with the personal protective equipment (PPE) they require to 
perform their work. The user manual must be kept in a location where it is available to all personnel 
working at the appliance.

The operator is furthermore responsible for ensuring that the appliance is in proper technical condition 
at all times. The specified maintenance intervals must be observed. The operator must establish a 
procedure that keeps the appliance or individual parts from being put into operation until all maintenance 
steps have been completed properly and in a timely manner.

The operator must keep all safety instructions and warnings attached to the appliance in legible 
condition and replace them as necessary.

5. Technical specifications

The type plate of the appliance is found on the housing.

Warning:

 

ƒ

Do not use the appliance without knowledge of the user manual.

 

ƒ

Do not use the appliance without the filter insert.

 

ƒ

Do not block the intake vents of the appliance on multiple sides during operation.

 

ƒ

Do not insert any foreign objects into the appliance.

 

ƒ

Do not climb onto the appliance.

 

ƒ

The appliance is not intended for use in medical or industrial environments.

 

ƒ

The appliance is not suited for vacuuming off dust.

 

ƒ

The appliance is not designed to vacuum off burning or smoldering materials or 
gases that are easily flammable or explosive.

 

ƒ

Do not operate the appliance unless it is in a stable position.

 

ƒ

Not designed for operation in damp rooms.

 

ƒ

Do not operate in the immediate vicinity of heat sources.

 

ƒ

The appliance is not suited for use in explosive atmospheres.

Length (mm)

407

Width (mm)

457

Height (mm)

1086

Sound pressure level at distance of 1 m at 
nominal power (dB (A))

Sound pressure level at distance of 1 m at 
maximum volume flow (dB (A))

42 under free-field conditions

48 under free-field conditions

Filter change interval (months)

approx. 6

Serial numbers

13030000AB_01_21_00001 to 
13030000AB_01_21_XXXXX

Installed power (kW)

0.76

Rated current (A)

3.3

Appliance fuse (A)

         T5.0

Voltage/frequency (V/Hz)

230 V~50 Hz

Degree of protection

IP X0

Rated volume flow (m³/h)

600

Filter efficiency

≥ 99.995 % of all particles including bacteria and 
viruses

Filter combination

HEPA H14 filter set

Environmental temperature - transport (°C)

-25 °C - 55 °C

Environmental temperature - operation (°C)

10 °C - 40 °C

Relative humidity (%)

20 % - 70 % (non-condensing)

Air quality

Non-condensing

Total weight (kg)

50

Summary of Contents for Blue.care plus

Page 1: ...1 Original User Manual Item number 130 300 000 I Subject to change EN Original User Manual ...

Page 2: ...d warnings 4 2 Appliance description and scope of supply 6 3 Transport and packaging 7 4 Intended use 9 5 Technical specifications 11 6 Initial operation 12 7 Operation 13 8 Cleaning maintenance and spare parts 14 9 Fault finding and troubleshooting 18 10 Disposal 19 11 Limitation of liability 19 12 EC Declaration of Conformity 20 13 Maintenance table 22 Contents ...

Page 3: ...e extent of the danger Follow the safety instructions carefully and act with caution to prevent accidents personal industry and damage to property Danger This symbol signifies an immediate risk to the life and the health of persons Failure to observe this information will lead to serious health effects including life threatening injuries Warning This symbol signifies a potential risk to the life a...

Page 4: ...an outflow opening Scope of supply Please check if the shipment is complete by comparing it to the specified scope of supply Antiviral air purifier with built in HEPA H14 filter set Power cord Key for the maintenance door User guide 3 Transport and packaging Safety instructions Warning There is a risk of injury during transport due to the great weight of the packing unit When loading the packing u...

Page 5: ... to its weight 4 Intended use The air purifier reduces the concentration of germs and viruses including corona viruses For this purpose the room air is sucked in through a filter system with the help of a fan and dispersed into the room through an outflow opening The Blue care operates with a HEPA H14 filter set that provides for effective air purification The air purifier is capable of purifying ...

Page 6: ...hnical condition at all times The specified maintenance intervals must be observed The operator must establish a procedure that keeps the appliance or individual parts from being put into operation until all maintenance steps have been completed properly and in a timely manner The operator must keep all safety instructions and warnings attached to the appliance in legible condition and replace the...

Page 7: ...mes Engage the caster brakes and verify that the appliance is standing firmly Connect the appliance to the power supply system and lay the cord such that no one can trip over it Use the ON OFF switch to turn the appliance on off The ON OFF switch is lit when the appliance is switched on Operation is not permitted unless the filter is installed properly The appliance can only be adjusted to the siz...

Page 8: ...uctions Exterior cleaning Prior to cleaning the appliance always has to be taken out of service and disconnected by pulling the power plug Use a sufficiently damp cloth and a common cleaning agent for cleaning The work necessary to care for the appliance is largely limited to a regular cleaning of the surfaces No liquids must enter into the electrical parts or through the vent slots Do not use cle...

Page 9: ...nt towards the maintenance door while the arrows on the filters point in flow control direction 9 Slide in the prefilter all the way and insert it behind the metal rail The main filter must be pushed in all the way above the prefilter 10 Close both locks of the tensioner Verify that the filters are clamped tightly and that the seal of the main filter abuts tightly at the top on the appliance housi...

Page 10: ...te However please follow all applicable legal provisions and local regulations as well Dispose of the appliance the filter and the packaging materials as prescribed in the applicable legal provisions and local regulations Waste electrical and electronic equipment marked with this symbol must not be disposed of with unsorted domestic waste but needs to be collected separately instead Help protect t...

Page 11: ...ment and risk reduction ISO 12100 2010 German version EN ISO 12100 2010 DIN EN ISO 14120 2016 05 Safety of machinery Guards General requirements for the design and construction of fixed and movable guards ISO 14120 2015 German version EN ISO 14120 2015 DIN EN ISO 13857 2019 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs ISO 13857 2019 German ver...

Page 12: ...ber 130 300 000 I Subject to change Original User Manual Item number 130 300 000 I Subject to change EN EN 13 Maintenance table Number Filter change performed on Signature 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ...

Page 13: ...Hengst SE Nienkamp 55 85 48147 Münster Tel 49 251 20202 0 luftreiniger hengst de www hengst com air purifier ...