USER’S MANUAL
30
4.3.3-1 4.3.3-2 4.3.3-3
4.3.3-4 4.3.3-5 4.3.3-6
4.3.4 Replace the bottom tank UV
①
Before replacing, soft touching the “
” icon until the machine enter stand-by condition
(diagram 4.3.4-1) and unplug power cord, wait for about 10 minutes to let UV light to cool off;
②
Pull out bottom tank (diagram 4.3.4-2);
③
Pull out bottom tank UV light connection pin (diagram4.3.4-3);
④
Unscrew UV light assembly plastic (daigram 4.3.4-4) and take out UV light (daigram 4.3.4-5);
⑤
Replace new UV light glass tube (diagram 4.3.4-6); Apply silicon between the UV light cords
and assembly (daigram 4.3.4-7); Wait until the silicon dry up and screw back on the plastic
screw plate (diagram 4.3.4-8);
⑥
Connect UV light connection pin and push back bottom tank.