ATMOSPHERIC WATER GENERATOR
23
the filter) (diagram 4.1.4-10), put back the filter cup after cleaning and fill the bottom tank
with tab water;
⑧
Turn on the machine and start cleaning the water system, pay attention to the bottom tank
water level, keep filling with tab water if necessary until water is free of any odor (need to
circulate about 20 liters of water). Avoid starring at the UV light directly when adding water
to the bottom tank;
4.1.4-5 4.1.4-6 4.1.4-7 4.1.4-8
⑨
After cleaning, follow the water circulating order, reconnect and secure all tube connectors,
make sure to double check for any leakage (diagram 4.1.4-11);
⑩
Put back on front panel (diagram 4.1.4-12), turn on machine, begin cleaning the RO
membrane by letting the machine run itself or fill up bottom tank with city water;
⑪
Soft touching the “
” icon (diagram 4.1.4-13); Then touch “
” to unlock then touch the
“
” icon (diagram 4.1.4-14, 4.1.4-15) dispense 2 liters of water from the spout; Turn off
the machine and drain out the rest of the water from the outlet locating at the back of the
machine (diagram 4.1.4-16).