ATMOSPHERIC WATER GENERATOR
35
Problem Nine:
Water output from faucet is too small.
Solutions:
①
Clean the filter net inside water faucet or replace with new one.
②
Unscrew water tap, adjust and install the nano flter net and silicon sealing ring inside in
place ,screw water tap bace to its original position.
Problem Ten: No hot or cool water output but with ambient water only.
Solutions:
①
The heating function will be activated only when top tank water level on screen is above two
levels.
②
The cooling function will be activated only when top tank water level on screen is above
three levels.
Problem Eleven: The machine makes water at a slow rate even after prolonged period of
operation.
Solutions:
①
Make sure the temperature level is in appropriate range.
②
Check the humidity level in the room. Low humidity level results in less water production.
③
Make sure that the hot/cold water spouts are not blocked.
④
Make sure that the ingoing and outgoing air ventilation is not blocked.
⑤
Check that the distance between the machine and the wall is not too close.
⑥
Make sure that the power voltage is not too low or too high.
⑦
Make sure that the internal booster pump is working well.