6.2 Maintenance of the Peristaltic Tube 

and Roller Holder

The Henden pH Dosing Pump uses a roller holder and 
a “squeeze” tube to pump the acid into the pool. This 
tube is perishable and must be replaced periodically. We 
recommend replacement approximately once per year. 
The tube should be visually inspected regularly for leaks 
or damage. It is recommended that the roller holder be 
periodically inspected and replaced every 2 years.

6.3 Maintenance of the Probe

Over time, in addition to the normal wear of the probe, 
according to use and water quality that is more or less 
calcareous, measurement will deteriorate. A thin layer of 
limestone with other elements present in the pool water 
will deposit on the sensing element of the probe. For 
assistance in overcoming this issue, please contact: 
 1300 HENDEN (1300 436 336).

6.4 Controller Wintering

Only in areas where subzero temperatures are experienced

• 

During winterising, you must protect the peristaltic tube.

• 

It is advisable to remove the peristaltic tube and flush 
it with fresh water. Once complete ensure the tube is 
completely dry and re-install.

6.5 Probe Wintering

• 

During winterising, the probe must be removed from of the 
installation and pipe work.

• 

The protection cap as shown on page 8, must be filled with 
fresh water a 1/3 of the way up.

• 

Place the probe into the protection cap and water and store 
in a safe place until after the winter period is over. (Re-
install as shown on page 8.

7. TROUBLE SHOOTING

Error

Reasons

How to solve it

CAL Err

If this error is 
displayed during the 

calibration phase and 

cycle it is as a result 
of:
1. Your pH probe 

is not working 
properly

2. Your buffer 

solution is polluted

3. You have water/

oxidisation in the 
probe connector

1. Change the probe
2. Change the buffer 
solution
3. Change over the 
probe

Alarm Alr Err

If the pH is lower 
than pH 5 or above 

pH 9, this alarm 
will be displayed 
and dosing will be 
stopped.

Adjust your water 
parameter manually 

so that it comes back 
to the required value 
of these parameters:
- Total alkalinity
- TH (hardness)
- pH
The dosing pump will 
restart as soon as the 

pH reading

If trouble persists, please contact Henden (1300 HENDEN) or 
your local Reece Irrigation & Pools branch. For assistance in 
locating your nearest branch visit reece.com.au/storefinder

Summary of Contents for HPHDB

Page 1: ...ing Pump HPHDB WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual ...

Page 2: ......

Page 3: ...unting of the Probe on the Probe Holder 6 3 2 4 Mounting of Injection Valve 6 3 2 5 Mounting of the Tube into the Injection Valve 7 4 CONNECTING THE POWER AND POOL PUMP TO YOUR PH CONTROLLER 7 OWNERS MANUAL 5 COMMISSIONING AND OPERATION 8 5 1 Calibration Procedure 8 5 2 Important Points 8 5 3 Settings 9 5 3 1 Adjustment of the Set Point 9 5 4 Operating Principle 9 6 MAINTENANCE 9 6 1 Replacement o...

Page 4: ...ed in the state or country under consideration Use of electrical equipment always implies observance of some basic rules In particular Do not touch with wet or damp hands or feet Do not operate the Henden pH Dosing Pump with bare feet example swimming pool equipment Do not leave the equipment exposed to atmospherit agents Do not allow the Henden pH Dosing Pump to be used by children or unskilled i...

Page 5: ...t of product needed to maintain the balance of the pool water The pump works in acid pH or basic pH dosage 2 1 Parts Description Here are the complete contents of the package you received All parts will be necessary for the proper operation of your device 2 2 Pump Interface A Peristaltic pump x 1 B 4 meters of PVC Cristal tube x 1 C Screws for wall mounting x 2 D Masonry plugs for wall mounting x ...

Page 6: ...f the pipe work through the clamp 14 mm for the electrode pH probe Fig 6 E E 3 2 3 Mounting of the pH Probe into the Probe Holder After removing the protective cap from the probe you need to insert all the parts as shown in the Fig 7 Before inserting the probe into the pipe make sure you calibrate the probe refer to 5 1 Calibration Procedure for instructions Once the probe has been constructed as ...

Page 7: ...the pump 1 Slide the tube through the nut 2 Put the tube at the bottom of the conical nipple 3 Screw the nut by hand onto the nipple 4 CONNECTING THE POWER AND POOL PUMP TO YOUR PH CONTROLLER Connection diagram for the Henden pH Dosing Pump The Henden pH Dosing Pump system should ideally be plumbed and connected up as shown in the diagram below If your pool pump is plugged into your Chlorinator 1 ...

Page 8: ...seat Shutter Washer O ring Fig 11 5 2 Important Points To ensure the probe signal remains as accurate as possible please follow the procedure as listed below during the commissioning of the pool and every 3 4 weeks thereafter or as required The procedure is renewed in case of abnormal consumption of chemicals 1 Remove the protective cap of the probe and keep it for reuse at the time of winterising...

Page 9: ...the value of the set point press SET and press CAL by pulse Each pulse changes the pH value by 0 1 pH between 7 0 and 7 6 5 4 Operating Principle The Henden pH Dosing Pump adjusts its dosage in proportion to the demand It will dose less if the displayed measure is near the set point In normal operation the pump will increase its non operational time period proportional to the required dosage deman...

Page 10: ...tic tube and flush it with fresh water Once complete ensure the tube is completely dry and re install 6 5 Probe Wintering During winterising the probe must be removed from of the installation and pipe work The protection cap as shown on page 8 must be filled with fresh water a 1 3 of the way up Place the probe into the protection cap and water and store in a safe place until after the winter perio...

Page 11: ...or which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorized persons attempting repairs Where applicable your Henden product must only be connected to the voltage shown on the nameplate Henden does not c...

Page 12: ...P N 403229 2 ...

Reviews: