10
|
HENDEN
INSTALLATION & OWNERS MANUAL
Henden pH Dosing Pump Owners Manual
6.2 Maintenance of the Peristaltic Tube
and Roller Holder
The Henden pH Dosing Pump uses a roller holder and
a “squeeze” tube to pump the acid into the pool. This
tube is perishable and must be replaced periodically. We
recommend replacement approximately once per year.
The tube should be visually inspected regularly for leaks
or damage. It is recommended that the roller holder be
periodically inspected and replaced every 2 years.
6.3 Maintenance of the Probe
Over time, in addition to the normal wear of the probe,
according to use and water quality that is more or less
calcareous, measurement will deteriorate. A thin layer of
limestone with other elements present in the pool water
will deposit on the sensing element of the probe. For
assistance in overcoming this issue, please contact:
1300 HENDEN (1300 436 336).
6.4 Controller Wintering
Only in areas where subzero temperatures are experienced
•
During winterising, you must protect the peristaltic tube.
•
It is advisable to remove the peristaltic tube and flush
it with fresh water. Once complete ensure the tube is
completely dry and re-install.
6.5 Probe Wintering
•
During winterising, the probe must be removed from of the
installation and pipe work.
•
The protection cap as shown on page 8, must be filled with
fresh water a 1/3 of the way up.
•
Place the probe into the protection cap and water and store
in a safe place until after the winter period is over. (Re-
install as shown on page 8.
7. TROUBLE SHOOTING
Error
Reasons
How to solve it
CAL Err
If this error is
displayed during the
calibration phase and
cycle it is as a result
of:
1. Your pH probe
is not working
properly
2. Your buffer
solution is polluted
3. You have water/
oxidisation in the
probe connector
1. Change the probe
2. Change the buffer
solution
3. Change over the
probe
Alarm Alr Err
If the pH is lower
than pH 5 or above
pH 9, this alarm
will be displayed
and dosing will be
stopped.
Adjust your water
parameter manually
so that it comes back
to the required value
of these parameters:
- Total alkalinity
- TH (hardness)
- pH
The dosing pump will
restart as soon as the
pH reading
If trouble persists, please contact Henden (1300 HENDEN) or
your local Reece Irrigation & Pools branch. For assistance in
locating your nearest branch visit reece.com.au/storefinder