 Henden pH Dosing Pump Installation Manual 

3. INSTALLATION RECOMMENDATIONS

3.1 Recommendations

• 

Install the Henden pH Dosing Pump in a dry place and 
well away from sources of heat and in environments not 
exceeding 45°C. The operating minimum temperature 
depends on the liquid to be pumped, bearing in mind that 
it must always remain in a liquid state.

• 

Carefully observe any standards in force in your 
state, territory or country, as to electrical installation 
regulations and requirements.

• 

The Henden pH Dosing Pump should be in operation only 
when your filtration pump is running.

3.2 Mounting the Pump

3.2.1 Bracket

1.  Locate the bracket in the space chosen and mark the holes
2.  Drill the holes as required (3mm for timber walls & 6mm for 

masonry walls) 

3.  Fix the bracket to the wall
4.  Slide and secure pump into the bracket

Ø4mm

Ø6mm

35mm

Fig. 4

3.2.2 Mounting of the Probe Clamp

Choose a mounting location on your pipework that is:
1.  Prior to your salt cell
2.  BEFORE the placement of the acid injection point
3.  Ensure the probe clamp lead is within reach of the 

Henden pH Dosing Pump controller

Fig. 5

O-ring

Nut

Pierce the top wall of the pipe work through the clamp:
- 14 mm for the electrode/pH probe.

Fig. 6

E

E

3.2.3 Mounting of the pH Probe into the  

Probe Holder

After removing the protective cap from the probe, you 
need to insert all the parts as shown in the Fig.7.
Before inserting the probe into the pipe make sure you 
calibrate the probe (refer to 5.1 Calibration Procedure for 
instructions).
Once the probe has been constructed as indicated in Fig.7, 
tighten the probe nut without crimping the probe body. 
Push the probe approximately 20mm into the pipe work so 
that the probe tip is approximately halfway into the pipe 
work. Connect the probe lead to the BNC terminal on the 
pump. (Fig8)

Nut

Disk brake

Washer seat

O-ring

Bracket

Fig. 7

WARNING

• 

It is important to keep a minimum 
distance of 200mm between the probe 
“C“ and the injection valve “E”

• 

The injection valve “E” must be 
placed last in the pipework hydraulic 
installation

• 

In the case of an installation with 
redox and pH regulation, it is advised 
to put the two sensors side by side 
and the pH injection before chlorine 
injection to minimise the risk of scale 
deposition on the chlorine injection

• 

For optimal service life of your 
peristaltic pump tube, it is advised 
not to exceed a pressure of 1 bar and 
under no circumstances exceed a 
pressure of 1.5 bar

• 

The pH probe must be located before 
any other device such as a heater or 
an electrolyser

Summary of Contents for HPHDB

Page 1: ...ing Pump HPHDB WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual ...

Page 2: ......

Page 3: ...unting of the Probe on the Probe Holder 6 3 2 4 Mounting of Injection Valve 6 3 2 5 Mounting of the Tube into the Injection Valve 7 4 CONNECTING THE POWER AND POOL PUMP TO YOUR PH CONTROLLER 7 OWNERS MANUAL 5 COMMISSIONING AND OPERATION 8 5 1 Calibration Procedure 8 5 2 Important Points 8 5 3 Settings 9 5 3 1 Adjustment of the Set Point 9 5 4 Operating Principle 9 6 MAINTENANCE 9 6 1 Replacement o...

Page 4: ...ed in the state or country under consideration Use of electrical equipment always implies observance of some basic rules In particular Do not touch with wet or damp hands or feet Do not operate the Henden pH Dosing Pump with bare feet example swimming pool equipment Do not leave the equipment exposed to atmospherit agents Do not allow the Henden pH Dosing Pump to be used by children or unskilled i...

Page 5: ...t of product needed to maintain the balance of the pool water The pump works in acid pH or basic pH dosage 2 1 Parts Description Here are the complete contents of the package you received All parts will be necessary for the proper operation of your device 2 2 Pump Interface A Peristaltic pump x 1 B 4 meters of PVC Cristal tube x 1 C Screws for wall mounting x 2 D Masonry plugs for wall mounting x ...

Page 6: ...f the pipe work through the clamp 14 mm for the electrode pH probe Fig 6 E E 3 2 3 Mounting of the pH Probe into the Probe Holder After removing the protective cap from the probe you need to insert all the parts as shown in the Fig 7 Before inserting the probe into the pipe make sure you calibrate the probe refer to 5 1 Calibration Procedure for instructions Once the probe has been constructed as ...

Page 7: ...the pump 1 Slide the tube through the nut 2 Put the tube at the bottom of the conical nipple 3 Screw the nut by hand onto the nipple 4 CONNECTING THE POWER AND POOL PUMP TO YOUR PH CONTROLLER Connection diagram for the Henden pH Dosing Pump The Henden pH Dosing Pump system should ideally be plumbed and connected up as shown in the diagram below If your pool pump is plugged into your Chlorinator 1 ...

Page 8: ...seat Shutter Washer O ring Fig 11 5 2 Important Points To ensure the probe signal remains as accurate as possible please follow the procedure as listed below during the commissioning of the pool and every 3 4 weeks thereafter or as required The procedure is renewed in case of abnormal consumption of chemicals 1 Remove the protective cap of the probe and keep it for reuse at the time of winterising...

Page 9: ...the value of the set point press SET and press CAL by pulse Each pulse changes the pH value by 0 1 pH between 7 0 and 7 6 5 4 Operating Principle The Henden pH Dosing Pump adjusts its dosage in proportion to the demand It will dose less if the displayed measure is near the set point In normal operation the pump will increase its non operational time period proportional to the required dosage deman...

Page 10: ...tic tube and flush it with fresh water Once complete ensure the tube is completely dry and re install 6 5 Probe Wintering During winterising the probe must be removed from of the installation and pipe work The protection cap as shown on page 8 must be filled with fresh water a 1 3 of the way up Place the probe into the protection cap and water and store in a safe place until after the winter perio...

Page 11: ...or which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorized persons attempting repairs Where applicable your Henden product must only be connected to the voltage shown on the nameplate Henden does not c...