Henden pH Dosing Pump Owners Manual
OWNERS MANUAL
5. COMMISSIONING AND OPERATION
5.1 Calibration Procedure
This operation is used to set the sensor response reading
of the pH and peristaltic pump.
Before carrying out the calibration of the probe, remember to:
•
Stop the filtration pump
•
Close the isolation valves, if fitted
•
Remove the probe from the probe holder
•
Put the shutter washer (fig. 12) in to close off the hole in the
probe holder
•
Open the isolation valves, if fitted
•
Turn on the filtration pump and check that the ON/OFF switch
(I/O) of the pump is switched to “I”
•
Carry out the calibration of the probe and repeat the previous
actions to put the probe back in place. As described in 3.2.3
Nut
Disk brake
Washer seat
Shutter Washer
O-ring
Fig. 11
5.2 Important Points
•
To ensure the probe signal remains as accurate as possible,
please follow the procedure as listed below during the
commissioning of the pool and every 3-4 weeks thereafter,
or as required.
•
The procedure is renewed in case of abnormal consumption of
chemicals.
1. Remove the protective cap of the probe and keep it for
reuse at the time of winterising.
Probe
Protective
Cap
2. Rinse the probe in tap water for at least 20 minutes.
3. Next immerse the probe in the pH 7 solution, stir around
in bottle and leave it in the solution being careful not to
touch the probe or the cable.
4. After a period of at least one minute, the stabilised
value is displayed. Press the CAL button until the display
shows CAL flashing then release. The quality of the
probe reading is then briefly displayed.
CAL
SET
pH -
5. The calibration of the Henden pH Dosing Pump is
completed: It is now ready to measure the pH of
your pool.