background image

9

5

- Check the immunity of any other equipment operating in the same environment.

 In certain cases additional protective measures may be required.

Interference can be reduced in the following ways:

1

- If there is interference in the power supply     line, an E.M.C. fi lter should be 

inserted between the mains and the unit.

2- 

The output cables of the unit should be shortened; these should be kept close 

together and stretched along the ground.

3- 

All the panels of the unit should be correctly closed after carrying out 
maintenance.

2.8 Medical and fi rst aid treatment

First aid facilities and a qualifi ed fi rst aid person should be available for each shift 
for immediate treatment of electrical shock victims. A medical facility should be close 
by for immediate treatment of fl ash burns of the eye and skin burns.

EMERGENCY FIRST AID:
Call physician and ambulance immediately. 
Use First Aid techniques recommended by The Red Cross.
DANGER: ELECTRIC SHOCK CAN BE FATAL

If person is unconscious and electric shock is suspected , do not touch the 
person if he or she is in contact with welding equipment, or other live electrical 
parts. Disconnect (open) power at wall switch and then use First Aid. Dry wood, 
wooden broom, or other insulating material can be used to move
 cables, if necessary, away from the person. 

2.5 Shielding gas

Use the correct shielding gas for the welding process. Be sure that the regulator/
fl owmeter mounted on the cylinder is working well.
Remember to keep away the cylinder from any source of heat.

2.6 Permitted noise levels 86/188/EEC Rule.

Under normal circumstances the equipment used for electric arc welding does 
not exceed the permitted 80 dBA. However in certain conditions eg. high welding 
parameters in confi ned spaces, noise levels may exceed the permitted level. For this 
reason it is strongly recommended that operatives wear appropriate ear protection.

2.7 Electromagnetic compatibility.

Before installing the STICK/TIG welding  unit, carry out an inspection of the 
surrounding area, observing the following guidelines:

1

- Make sure that there are no other power supply cables, control lines, telephone 

leads or other equipment near the unit.

2

- Make sure that there are no radio receivers or television appliances.

3

- Make sure there are no computers or other control systems.

4- Make sure that there is no-one with a pacemaker or hearing aid in the area 
around the unit.

Summary of Contents for GLOBUS 201

Page 1: ...E READ THESE INSTRUCTIONS BEFORE INSTALLING OPERATING OR SERVICING THIS PRODUCT DO NOT DISTROY THIS MANUAL LEGGETE LE ISTRUZIONI PRIMA DI INSTALLARE UTILIZZARE O RIPARARE QUESTO IMPIANTO CONSERVATE QU...

Page 2: ...e 19 14 0 Technical data information guide 20 ITALIANO pag 1 0 Introduzione 22 2 0 Precauzioni sulla sicurezza 22 3 0 Caratteristiche generali 28 4 0 Installazione dell apparecchiatura 30 5 0 Globus 3...

Page 3: ...E UNIT MUST NEVER BE OPERATED WITHOUT PANELSAS THIS COULD BE DANGEROUS FOR THE OPERATOR AND COULD CAUSE SERIOUS DAMAGE TO THE EQUIPMENT THE UNIT WORKS ONLY WITH INPUT VOLTAGE OF 230Vac 50 Hz 1Ph ALWAY...

Page 4: ...s This manual contains all the necessary instructions for the installation of the equipment a correct operating procedure an adequate maintenance of the equipment Therefore be sure this manual is care...

Page 5: ...osits greatly reduce visibility When working with coated plates that emit toxic fumes when heated use an air supplied respirator Welding should be done in a closed area that does not open onto other w...

Page 6: ...soreness to the eyes the nose or the throat may be cause by inadequate ventilation work must be stopped immediately and all necessary steps must be taken to rpovide adequate ventilation Welding proces...

Page 7: ...ade with a two pole plug compatible with the above mentioned socket two wires of the two pole input cable are used for the connection with the mono phase line and the yellow green wire for the compuls...

Page 8: ...containers in which fuel lubricant or any other flammable material have been stored After having completed your work always check that the area is free of glowing or smouldering material FIG 10 the o...

Page 9: ...or other live electrical parts Disconnect open power at wall switch and then use First Aid Dry wood wooden broom or other insulating material can be used to move cables if necessary away from the per...

Page 10: ...by a switching transformer and a levelling inductance In the p c board are included different electronic functions in order to improve the arc striking and the dynamic of the welding so that we can ac...

Page 11: ...230 PHASES 1 1 1 FREQUENCY Hz 50 60 50 60 50 60 OUTPUT CURRENT A 200 155 200 60 V 28 26 2 28 OUTPUT CURRENT A 155 120 155 100 V 26 2 24 8 26 2 NO LOAD VOLTAGE V 80 80 80 PROTEC DEGREE IP22 IP22 IP22 I...

Page 12: ...chine are not obstructed poor air ventilation may reduce the duty cycle of the unit and cuase damages Now you may choose the welding process by connecting the accessories as showed in the following pa...

Page 13: ...onds and then it stops 2 Yellow Led it glows indicating overtemperature cutout Let the unit to cool down Thermostat will automatically reset and you can continue welding 3 Tig Stick Selector 4 Welding...

Page 14: ...ter and the earth clamp to the workpiece Connect the welding cable to the positive pole of the Inverter Select the welding current using the potentiometer on the front panel the welding current should...

Page 15: ...ing speed The correct welding speed will consent to achieve a weld of proper width without waves or craters 8 0 TIG WELDING The TIG process uses the electrical arc struck between the tungsten electrod...

Page 16: ...t the torch nozzle protrudes by 4 5mm also ensure that the electrode is sharply pointed with an angle of 40 60 Set the welding current considering the thickness of the material to be welded and of the...

Page 17: ...ing current considering the thickness of the material to be welded andof the diameter of the tungsten electrode to be used Switch the inverter on Covering your face with a mask or a helmet bring the t...

Page 18: ...18 12 0 TROUBLE SHOOTING 11 0 POSSIBLE WELDING DEFECTS...

Page 19: ...e dustier the working environment is the more often this should be done Take off the lid Remove all traces of dust in the inner parts of the generator with a jet of compressed air at a pressure under...

Page 20: ...process symbol 6 Input supply and no of phases 7 Rated supply voltage 8 Code letter for degree of insulation 9 Degree of protection 10 Input Power 11 Size of the necessary main fuse 12 Rated supply c...

Page 21: ...A I PANNELLI IN QUANTO CIO POTREBBE ESSERE PERICOLOSO PER L OPERATORE E POTREBBE CAUSARE GRAVI DANNI ALL ATTREZZATURA L APPARECCHIOLAVORASOLTANTOCONUNATENSIONEDIALIMENTAZIONE DI 230Vac 50Hz 1Ph POSIZI...

Page 22: ...tte le istruzioni necessarie per l installazione della sorgente di saldatura un corretto utilizzo un adeguata manutenzione Assicuratevi che questo manuale venga letto e capito sia dall operatore che d...

Page 23: ...lit Utilizzate un respiratore quando lavorate con piastre rivestite che emettono fumi tossici se riscaldate FIG 2 L operazione di saldatura deve essere eseguita in un ambiente isolato rispetto alle al...

Page 24: ...gli occhi al naso o alla gola pu essere causato da una inadeguata ventilazione in tal caso interrompete immediatamente il lavoro e provvedete all adeguata ventilazione dell area FIG 6 Il procedimento...

Page 25: ...ata sopra i due fili del cavo di alimentazione a due poli sono impiegati per il collegamento con la linea mono fase mentre il filo giallo verde usato per il collegamento obbligatorio a terra nel luogo...

Page 26: ...tessa 2 4 Prevenzione di incendio L area di lavoro deve essere conforme alle norme di sicurezza quindi occorre siano presenti gli estintori Mentre il soffitto il pavimento e le pareti devono essere no...

Page 27: ...t di ogni strumento che opera nello stesso ambiente In casi particolari possono essere richieste misure di protezione aggiuntive Le interferenze possono venire ridotte seguendo questi accorgimenti 1 S...

Page 28: ...er serie Globus sono composti da una scheda di controllo di potenza da un trasformatore switching e da una impedenza Nella scheda ci sono diverse funzioni elettroniche che migliorano l innesco dell ar...

Page 29: ...GLOBUS 211 TENSIONE DI V 230 230 230 ALIMENTAZIONE FASI 1 1 1 FREQUENZA Hz 50 60 50 60 50 60 CORRENTE USCITA A 200 155 200 60 V 28 26 2 28 CORRENTE USCITA A 155 120 155 100 V 26 2 24 8 26 2 TENSIONE A...

Page 30: ...NNELLI LATERALI PARZIALMENTE O COMPLETAMENTE RIMOSSI AL FINE DI EVITARE IL CONTATTO ACCIDENTALE CON LE PARTI PIU INTERNE CHE SONO CARICHE il led verde deve essere acceso e quello giallo spento Se il l...

Page 31: ...l Led lampeggia per alcuni secondi e poi si spegne 2 Led giallo rimane acceso ad indicare blocco per sovratemperatura Lasciateraffreddareilgeneratore Iltermostatosiripristinaautomaticamente e si potr...

Page 32: ...struzioni fornite dal produttore degli elettrodi e scritte sulla confezione degli stessi Le indicazioni seguenti possono essere utili come informazioni generali Accendete l inverter I due leds sul pan...

Page 33: ...ominciare a saldare scegliete il modello e il diametro dell elettrodo pi adatti prestando attenzione allo spessore e alla composizione del metallo da saldare e alla posizione della saldatura Corrente...

Page 34: ...9 0 SALDATURA ATIG CON PARTENZA A STRISCIO Assicuratevi che l elettrodo sporga dall ugello almeno 4 5mm assicuratevi anche che la sua punta sia a circa 40 60 dal pezzo Impostate la corrente di saldat...

Page 35: ...di saldatura considerando lo spessore del materiale che deve essere saldato e il diametro dell elettrodo a tungsteno da utilizzarsi Accendete l inverter Coprite il vostro viso con una maschera o un el...

Page 36: ...36 11 0 POSSIBILI DIFETTI DI SALDATURA 12 0 POSSIBILI INCONVENIENTI DI FUNZIONAMENTO...

Page 37: ...va eseguita tanto pi spesso quanto pi polveroso l ambiente di lavoro Togliete la copertura Togliete ogni traccia di polvere dalle parti interne del genratore mediante getto d aria compressa con press...

Page 38: ...entazione e numero di fasi 7 Tensione nominale di alimentazione 8 Codice del grado isolamento 9 Grado di protezione 10 Potenza in entrata 11 Valore del fusibile di linea 12 Corrente nominale di alimen...

Page 39: ...ux de collecte des quipements usag s veuillez contacter votre mairie votre service de traitement des d chets m nagers ou le magasin o vous avez achet le produit ENTSORGUNG VON ELEKTROGER TEN DURCH BEN...

Page 40: ...COD 77611050...

Reviews: