![Helvi 21905151 Instruction Manual Download Page 20](http://html1.mh-extra.com/html/helvi/21905151/21905151_instruction-manual_2123036020.webp)
20
SHOULDER STRAP & BELT CUSHION
•
Connect hooks to belt (See fig.24).
•
Connect with the blower by screw locking (See
fig.25).
FIG. 21
FIG. 22
FIG. 23
O-Ring
Breathing tube
Before using respirator - Check the following items.
Blower Assembly
Make sure the spark screen, pre-filter and particulate
filter (gas filter if any) are properly installed and secu
-
rely latched.
Breathing Tube
Make sure tube is not damaged and connected locked
to the blower unit and helmet.
Battery
Check connection to blower unit is secure and battery
is fully charged.
Check connection to blower unit is secure and bat-
tery is fully charged.
It’s necessary to do both airflow rate test and alarm
sound check before use. Testing method refers to the
next section.
AIR FLOW CONTROL
Two indicator lights on display (See fig.26) Low Speed-
170+lpm; High Speed-210+lpm.
When turn on the unit, default setting is low speed air
-
flow; Switch the airflow by short press the Button (See
fig.27).
FIG. 24
FIG. 25
Ganci
FIG. 26
FIG. 27
Low Speed - 170+lpm
High Speed - 210+lpm
ENTER AND EXIT
CONTAMINATED AREA
Face seal
Inspect face seal for damage and replace if necessary.
Make sure the air is supplied to helmet.
Always exit the contaminated area immediately if
any of the following conditions occur:
• IF some problem is shown in any part of the product,
for example, the air supply is stopped or its amount is
decreased;
• IF it gets hard to breathe, feeling dizzy or headache,
feeling the smell or taste of the contaminants and its
stimulus occurred;
• NEVER use in place with too high level of contamina
-
tion. If you suspect the levels reach a level which this
respirator may no longer provide enough protection.
RIMOZIONE DEL RESPIRATORE
WARNING
•
Never remove the respirator in areas where the air
is contaminated.
•
Always take off the unit after you step out of the
workplace.
• Take off helmet and disconnect tube from helmet.
•
Turn off the blower by long press button.
• Release belt. Remove straps from shoulders and
remove blower off of your lower back.
SELF CHECK BEFORE
EACH TIME USE
ALL THE TESTS MUST ALWAYS BE DONE IN A
SAFE ENVIRONMENT.
ALARM SOUND CHECK
After turning on the product, check the alarm sound
warning function by blocking the air outlet as fig.28
shown in the picture above. The warning signal on the
panel should flash with a sound and blower vibrate
(approximately 15 to 30 seconds after the outlet is blo-
cked). The product is working correctly if the warning
functions follow the process above.
(Please make sure the filter is equipped and the batte
-
ry is fully charged before doing this test.)
FIG. 28
Bloccare il
flusso dell’aria
con la mano