![Hellenbrand H200M HE Owner'S Manual Download Page 42](http://html1.mh-extra.com/html/hellenbrand/h200m-he/h200m-he_owners-manual_2121744042.webp)
42
H200M HE SPECIFICATIONS
Model
H200M HE-16
H200M HE-18
H200M HE-21
H200M HE-24
H200M QC HE-30 H200M QC HE-36 H200M QC HE-42 H200M QC HE-48
Factory Regeneration Settings
Cycle 1
Brine Draw UP
Minutes
84
84
116
84
90
134
150
160
Gallons
47.88
54.6
75.4
54.6
108
234.5
360
624
Cycle 2
Backwash
Minutes
12
12
12
12
12
12
12
12
Gallons
38.4
50.4
63.6
90
132
180
300
336
Cycle 3
Rinse
Minutes
8
8
8
8
8
8
8
8
Gallons
25.6
33.6
42.4
60
88
120
200
224
Cycle 4
Fill (POST)
Minutes
3.10
3.7
4.9
6.5
10.5
14.5
21.5
26
Gallons
6.82
8.14
10.78
14.30
23.10
31.90
43.00
52.00
Cycle 5
Optional
Total Regen Gallons*
118.7
146.7
192.2
218.9
351.1
566.4
903.0
1236.0
*Calculations are based on factory medium salt setting @ 35 psi
Refill Lbs
LBS
LBS
LBS
LBS
LBS
LBS
LBS
LBS
High Efficient salt @ 3.3 LBS/ CF
16.5
19.8
26.4
36.3
56.1
79.2
105.6
128.7
Low Salt @ 4 LBS/ CF
20.0
24.0
32.0
44.0
68.0
96.0
128.0
156.0
Refill Minutes
MIN
MIN
MIN
MIN
MIN
MIN
MIN
MIN
High Efficient salt @ 3.3 LBS/ CF
2.5
3.0
4.0
5.4
8.4
12.0
17.5
21.5
Low Salt @ 4 LBS/ CF
3.1
3.7
4.9
6.5
10.5
14.5
21.5
26.0
Grains
Grains
Grains
Grains
Grains
Grains
Grains
Grains
82,500
99,000
132,000
181,500
280,500
396,000
528,000
643,500
2
96,000
115,200
153,600
211,200
326,400
460,800
614,400
748,800
3
GPM
GPM
GPM
GPM
GPM
GPM
GPM
GPM
30
34
55
70
75
82
90
93
5
44
53
73
86
101
106
113
115
16x65
18x65
21x62
24x72
30x72
36x72
42x72
48x72
24X50
24X50
24x50
24x50
30x50
30x50
39x48
39x48
1
16/59
16/59
16/59
16/59
39/106
39/106
54/169
54/169
5"
5"
5"
5"
6"
6"
6"
6"
749
749
749
749
1140
1140
1949
1949
NO
NO
NO
NO
NO
NO
NO
NO
474
474
474
474
474
474
494
494
YES
YES
YES
YES
YES
YES
YES
YES
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1" Hard Pipe
3.2
4.2
5.3
7.5
11
15
25
28
2.2
2.2
2.2
2.2
2.2
2.2
2.0
2.0
2R
2S
2S
2S
2A
2B
2C
2D
4,800
5,700
7,600
10,250
16,000
23,000
30,000
37,000
4
2"
2"
2"
2"
2"
2"
2"
2"
3/4"
3/4"
3/4"
3/4"
1"
1.5"
1.5"
1.5"
1. Higher Salting may require different Grid hieght or larger brine tank
^^ 39x48 BT with 6" grid takes 6 hours to make brine with 8 bags of salt minimum
2. Factory default setting are shown in bold
3. Service Flows are with Hub and Lateral distributors and may be lower with a Stack distributor
4. Recommended minimum pipes sizes are copper pipe equivalent, when using PEX increase one nominal size
5. Demand Recall set points are factory set at 85% of service flow rate @ 15 psi loss
Upflow high efficiency water softeners are intended for clean water such as municipal supplies or well water applications
with proper pre-treatment. Operating parameters are for up to 0.5 ppm iron and 40 gpg hardness.
3/16/21
800780 Rev H
Inlet / Outlet
Recommended minimum pipe size
Drain Line
Shipping Weight (includes pallet)
Stock Code Number
Size of connections
Salt Storage Capacity lbs
BLFC on Valve
Safety Brine Valve
BLFC at Brine Tank
Brine Line Size
DLFC (gpm)
BLFC (gpm)
Injector Size
Factory Meter Setting (for single unit)
** Grid Height
Capacity - Efficiency
Efficient - 5000 grains/lb
Low Salt - 4800 grains/lb
Service Flow Rates
Continuous @ 10 psi loss
Peak @ 15 psi loss
Resin Tank Size
Recommended Brine Tank Size (Post-Fill)
Min/Max salt setting in Lbs
H200M HE Specifications
Summary of Contents for H200M HE