12
STEP 4S – Select the time for the second cycle (which in this example is SOFTENING) using the
or
button. Press NEXT to go to Step 5S. Press REGEN to return to the previous step.
STEP 5S – Select the time for the third cycle (which in this example is DRAW UP TIME) using the
or
button. Press NEXT to go to Step 6S. Press REGEN to return to the previous step.
STEP 6S – Select the time for the fourth cycle (which in this example is BACKWASH, setting) using
the
or
button. Press NEXT to go to Step 7S. Press REGEN to return to previous step.
STEP 7S – Select the time for the fifth cycle (which in this example is RINSE TIME, setting)
using the
or
button. Press NEXT to go to Step 8S. Press REGEN to return to previous step.
STEP 8S – Select between proportional or normal brining. Using the
or
button to select
Proportional brining is only available if configured as prefill/upflow softener or screen will not
appear. Proportional brining will divide the actual gallons used by calculated volumetric capacity then
multiply fill volume by this percentage. If regeneration is initiated by calendar day override it will brine
proportionately; minimum 20% of pre-programmed amount. This option requires a functioning meter.
Factory Setting = Normal brining. Press NEXT to go to Step 9S. Press REGEN to return to previous
step.
STEP 9S - Set Grain Capacity using the
or
button. The ion exchange capacity is in grains of
hardness as calcium carbonate for the system based on the pounds of salt that will be used. The allow-
able grains capacity range varies from 5,000 to 500,000 grains. The increment increase is 500 for the
range from 5000 to 50,000; 1000 for the range of 50,000 to 200,000; and 2000 for the range of 200,000
to 500,000. Grains capacity is affected by the fill time. The grains capacity for the selected lbs. salting
should be confirmed by testing. The capacity and hardness levels entered are used to automatically
calculate reserve capacity when gallon capacity is set to AUTO. Factory setting is the capacity of
the softener at low salting. See Page 38. Press NEXT to go to Step 10S. Press REGEN to return to
previous step.
STEP 10S – Set Gallons Capacity using
or
button. If value is set to:
• “AUTO” gallon capacity will be automatically calculated and reserve capacity will be automatically estimated;
• “oFF” regeneration will be based solely on the day override set (see Installer Display/Settings Step 3,
page 9 / proportional brining will not function if OFF selected); or
• as a number of gallons (allowable range 20 to 250,000) regeneration will be based on the value specified.
Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000 and 500 for the
range of 10,000 to 50,000 and 2000 for range of 50,000 to 250,000.
If “oFF” or a number is used, hardness cannot be set in Installer Displays/Settings Step 2, page 9. See
page 32 for more detail. Factory Setting is AUTO. Press NEXT to go to Step 10S. Press REGEN to
return to previous step.
STEP 11S – Set Regeneration Time Options using the
or
button. If value is set to:
• “DELAY” means regeneration will occur at the preset time; if control is set as Twin Alt, alternation will
occur on zero, but regeneration is delayed to preset time.
• “IMMEDIATE” means regeneration will occur immediately when the gallons capacity reaches 0 (zero);
or
• “DELAY + IMMEDIATE” means regeneration will occur at one of the following:
- the preset time when the gallons capacity falls below the reserve or the specified number of days be-
tween regenerations is reached, whichever comes first; or
- immediately after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
See page 32 for more options. Factory Setting is DELAY + IMMEDIATE. If control is set as Twin Alternat-
ing, this option is not available. Press NEXT to go to Step 10S. Press REGEN to return to previous step.
STEP 4S
SET
120
MIN
SOFTENING
➔
STEP 10S
RESERVE CALCULATOR
AUTO
➔
SET
STEP 9S
GRAIN OF CAPACITY
84.0
➔
x1K
SET
STEP 5S
DRAW UP TIME
➔
84
SET
MIN
STEP 6S
BACKWASH TIME
12
➔
SET
MIN
STEP 11S
DELAY + IMMEDIATE
REGEN
➔
SET
STEP 7S
RINSE TIME
8
➔
MIN
SET
STEP 8S
GRAIN OF CAPACITY
FILL
➔
SET
[!J
EJEJEJ [!7
[!J
EJEJEJ [!7
[!J
EJEJEJ [!7
[!J
EJEJEJ [!7
[!J
EJEJEJ [!7
[!J
EJEJEJ [!7
[!J
EJEJEJ [!7
[!J
EJEJEJ [!7