19
Step 3CS (continued) – If set up for a filter, in Step 7F set Volume Capacity in Gallons; in Step
8F select Regeneration Time Option “Immediate”; and in Step 3I select Day Override “oFF”.
For Clack Corporation alternator systems using the WS1, WS1.25, WS1.5 and WS2L valves,
there will be three choices for operation.
The first is Standard, where the regeneration proceeds in one complete sequence. After
regeneration is completed, the control enters Standby and remains there until the other control
initiates regeneration.
The third option is REFRESH RINSE. The stand-by tank will be periodically brought on line for a
short time to keep its bed fresh. The logic is that once a tank is in standby and the time has passed
either 6:00 AM or 6:00 PM at the next and all subsequent 6:00 AM and 6:00 PM times the stand by
tank will be brought on line until the preset number of gallons has passed through it. It will then be
placed back on stand-by.
WS2
Valve
WS1, WS1.25, WS1.5,
WS2L Valves
The second choice is to delay the last two cycles of regeneration (only “Rinse” and “Fill”). This
feature splits the regeneration into two portions. The first portion of the regeneration will start
immediately and all programmed cycles before the “Rinse” and “Fill” cycles will be performed.
After all programmed cycles before “Rinse” and “Fill” are completed the control valve will drive to
the service position (displaying “Delayed Rinse + Fill Pending”). When the volume of the on-line
unit is depleted to 10% of its programmed capacity, the control valve will be triggered to finish the
second portion of the regeneration. Once “Rinse” and “Fill” are completed, the valve will re-enter
Standby mode until requested to come on-line for Service. This selection is not available when set
to Filtering, Step 8S is set to OFF , or Step 9S is set to DELAY + IMMEDIATE.
For Clack Corporation alternator systems using the WS2 valve, when NEXT is pressed after selecting
ALTA or ALTB, a display will allow the user to set the amount of pre-service rinse time for the stand by
tank just prior to returning to service.
On the RINSE VOLUME screen
or
allow the refresh rinse volume to be adjusted from 5-100
gallons.