Installation instructions and Instructions for use
Subject to technical modifications
–
Date of Issue April/2022
69
Operating guidelines
Groups
In combination with ONYX.CENTER, groups with their different sun
protection systems/awning lightings can be configured freely in the ONYX
app. All units in one group can be controlled together.
Favourite position (heart symbol)
In the ONYX app, you can save up to six freely selectable brightness
options for each ONYX.LED, which you can use again later very easily.
Ideal use of the radio signal
In case of bad reception, the position of the
ONYX.CENTER/ONYX.CLICK must be changed.
Radio systems that send on the same frequency may cause interference
with reception.
It must be considered that the range of the radio signal is limited by
statutory regulations and structural measures.
Installation instructions and Instructions for use
70
Subject to technical modifications
–
Date of Issue April/2022
Fault removal
Problem
Possible cause
Troubleshooting
Lighting cannot be
controlled in the
ONYX app (offline).
No mains voltage at
the awning
Check the mains voltage and establish it if
necessary.
Poor or no radio
reception.
Adverse position of
the
ONYX.CENTER or
ONYX.CLICK
Change the position of the antenna of the
ONYX.CENTER or re-position
ONYX.CENTER/ONYX.CLICK
Disposal
Dispose of the device in accordance with the current country-specific
regulations for electronic scrap (e.g. suitable collecting points).
Installation instructions and Instructions for use
Subject to technical modifications
–
Date of Issue April/2022
71
Replacing a folding arm with integrated LED
lighting
Control of the LED lighting with the control module Somfy
Information about the commissioning and operation of the LED lighting are available in the
instructions for use “White LED Receiver io” from Somfy.
Legend
Power supply unit
Control module Somfy
Connection point
3
1
2
Installation instructions and Instructions for use
72
Subject to technical modifications
–
Date of Issue April/2022
Replacing a folding arm with integrated LED
lighting
The electrical works in the low-voltage range (230 V AC) may be carried
out by a qualified electrician only. This applies particularly to modification
works on the supply unit (230 V AC - input side). The entire LED System in
the extra-low-voltage range (24 V DC) is situated after the secondary
circuit of the supply unit. However, in the event of personal adjustments,
the manufacturer HELLA shall assume no liability or warranty.
During works on the LED circuit, all LED lighting must be switched off and
the entire power supply to the awning should be disconnected. To this
end, disconnect the power supply directly from the house! When removing
the awing, the parts that are under prestress (e.g. folding arms) must be
completely released from tension and protected against unintentional
extending before removal.