Installation instructions and Instructions for use
Subject to technical modifications
–
Date of Issue April/2022
53
Electric commissioning and overview table power
This general overview table shows which awning designs are possible with an electric
control.
Possible types of operation
Somfy
cord-bound
Somfy radio
io
ONYX
Cord
operated
Awning drive
yes
yes
yes
no
Varioplus roller blind
yes
yes
yes
no
LED lighting
no
yes
yes
no
Heater
no
no
no
yes
Installation instructions and Instructions for use
54
Subject to technical modifications
–
Date of Issue April/2022
Electric commissioning and overview table power
Technical data of the awning
Connection for all cables: 220-240V / 50-60Hz
Overview powers [W]
Installation instructions and Instructions for use
Subject to technical modifications
–
Date of Issue April/2022
55
Activation guidelines for electric drives
The motors we use are drives with integrated planetary gear, brakes, limit
stops at the top and at the bottom, and thermo cut-off switches, also not
only a motor, but a complete drive system.
In some respect, the drives do
NOT
correspond to other household
electrical consumers. Please strictly observe the following notes and
safety instructions.
The construction, checking, commissioning and error-correcting of the
electrical system are only allowed to be carried out by an electrician (acc.
to VDE 0100). In case of improper connection, considerable danger can
arise for the user.
-
Follow the wiring diagram precisely!
- We cannot accept responsibility for damage, that can result from
improper installation.
- Never simultaneously activate the drives with an UPWARDS and a
DOWNWARDS signal!
-
Keep a break of approx. 0.5 seconds between the UPWARDS and
the DOWNWARDS command
(is often neglected with Instabus EIB-
systems).
Radio interference suppression
The drives are provided with a radio interference suppression according to
the current VDE standards and EC Guidelines. If the drives are operated
with other devices, that include interferences, it is the fitter's duty - as part
of the obligation to suppress interference - to ensure that the entire unit
complies with the current regulations.
Operation in wet spaces
The drives are "splash-proof"; if they are operated in wet spaces, the VDE-
guidelines, inter alia VDE 0100/Parts 701, 702, the guidelines of the local
electric supply companies and of the TÜV must be observed and fulfilled.
Both the instructions and notes given in these instructions, as well
as the instructions and notes given in the respective enclosed
instructions of the manufacturers of the drive systems must be
observed.
Installation instructions and Instructions for use
56
Subject to technical modifications
–
Date of Issue April/2022
Wiring diagram for motors with switch operation
Drive system awning
Legend
Drive system awning
Hirschmann connector
Junction box
Switch
Mains
Drive system Varioplus
No PE available!
Legend
Drive system Varioplus
Junction box
Switch
Mains
For more details concerning the electrical connections, powers, operating
instructions and programming, please refer to the enclosed documents of
the manufacturer or the HELLA installation instructions.
It is essential that switches for the awning drive be electrically and
mechanically locked.
M
1
3
1 N
2
3
PE
2
4
1
5
L1 N PE
M
1
3
4
5
1
L1 N PE