background image

Installation instructions and Instructions for use

Subject to technical modifications 

Date of Issue April/2022

53

Electric commissioning and overview table power

This general overview table shows which awning designs are possible with an electric 
control.

Possible types of operation

Somfy 

cord-bound

Somfy radio 

io

ONYX

Cord 

operated

Awning drive

yes

yes

yes

no

Varioplus roller blind

yes

yes

yes

no

LED lighting

no

yes

yes

no

Heater

no

no

no

yes

Installation instructions and Instructions for use

54

Subject to technical modifications 

Date of Issue April/2022

Electric commissioning and overview table power

Technical data of the awning

Connection for all cables: 220-240V / 50-60Hz

Overview powers [W]

Installation instructions and Instructions for use

Subject to technical modifications 

Date of Issue April/2022

55

Activation guidelines for electric drives

The motors we use are drives with integrated planetary gear, brakes, limit 
stops at the top and at the bottom, and thermo cut-off switches, also not 
only a motor, but a complete drive system.

In some respect, the drives do 

NOT

correspond to other household 

electrical consumers. Please strictly observe the following notes and 
safety instructions.

The construction, checking, commissioning and error-correcting of the 
electrical system are only allowed to be carried out by an electrician (acc. 
to VDE 0100). In case of improper connection, considerable danger can 
arise for the user.
-

Follow the wiring diagram precisely!

- We cannot accept responsibility for damage, that can result from 

improper installation.

- Never simultaneously activate the drives with an UPWARDS and a 

DOWNWARDS signal!

-

Keep a break of approx. 0.5 seconds between the UPWARDS and 
the DOWNWARDS command

(is often neglected with Instabus EIB-

systems).

Radio interference suppression
The drives are provided with a radio interference suppression according to 
the current VDE standards and EC Guidelines. If the drives are operated 
with other devices, that include interferences, it is the fitter's duty - as part 
of the obligation to suppress interference - to ensure that the entire unit 
complies with the current regulations.

Operation in wet spaces
The drives are "splash-proof"; if they are operated in wet spaces, the VDE-
guidelines, inter alia VDE 0100/Parts 701, 702, the guidelines of the local 
electric supply companies and of the TÜV must be observed and fulfilled.

Both the instructions and notes given in these instructions, as well 
as the instructions and notes given in the respective enclosed 
instructions of the manufacturers of the drive systems must be 
observed.

Installation instructions and Instructions for use

56

Subject to technical modifications 

Date of Issue April/2022

Wiring diagram for motors with switch operation

Drive system awning

Legend

Drive system awning
Hirschmann connector
Junction box
Switch
Mains

Drive system Varioplus

No PE available!

Legend

Drive system Varioplus
Junction box
Switch
Mains

For more details concerning the electrical connections, powers, operating 
instructions and programming, please refer to the enclosed documents of 
the manufacturer or the HELLA installation instructions.
It is essential that switches for the awning drive be electrically and 
mechanically locked.

M

1

3

1 N

2  

PE

2

4

1

5

L1 N PE

M

1

3

4

5

1

L1 N PE

Summary of Contents for AREIA 7040

Page 1: ...tallation commissioning and use For authorized specialist staff For the consumer user The following symbols will assist you with the installation or use and require a safety conscious conduct Attention This symbol indicates instructions that if disregarded can put the user in danger Attention This symbol indicates instructions that if disregarded can potentially result in damage to the product Thi...

Page 2: ...easures against the danger of squashing especially when operating the unit with automatic devices Place the operating switch within sight of the unit but not near any of the moving parts Never let children play with the unit A sun protection device with electric drive cannot be retracted without current We therefore recommend the use of an emergency power generating unit or a motor with an emergen...

Page 3: ...in the colour Please note that the awning will cause a different colour effect in sunlight and in shade Naturally the optical colour perception depends on the composition and the intensity of the emerging light With increasing depth of colour more light will be absorbed and less will be reflected Therefore dark coloured covers let through a small amount of light while light colours let a lot of li...

Page 4: ...r retracted by turning the crank rod The respective direction of rotation depends on the drive side In the direction of extending the stop position of the gear is limited by an override In this position you hear a click when turning the crank handle beyond this stop Do not use force when turning towards the upper stop 1 2 3 3 Installation instructions and Instructions for use Subject to technical ...

Page 5: ... seriously Please strictly observe the installation instructions Close off the place of installation When working at higher heights there is risk of falling Suitable ascent supports scaffoldings and fall protection devices are to be used Please make sure that the ascent supports stand solidly and provide a firm grip Installation instructions and Instructions for use 18 Subject to technical modific...

Page 6: ...rackets Legend Arm bearing If a supporting bearing is provided in the centre then fix the brackets offset by approx 150 mm Outer edge of the awning tube bearing Possible bracket positions Max 400 mm Attention By default the unit is symmetric B C and E F The B C E and F dimension can be changed for asymmetric applications e g with rafters by 200 mm each Condition 1 Arm bearing dimension B and C min...

Page 7: ...e April 2022 27 Installation on concrete 60 200 mm ETICS Installation of the anchor rod as per approval ETA 02 0024 Drilled hole preparation ø18 mm Observe the anchoring depth and the minimum edge distance Drilled hole cleaning Fill drilled hole with mortar FIS V Slide the anchoring element into the drilled hole Wait for the curing time Installation of the Thermax as per approval Z 21 8 1837 Mill ...

Page 8: ...2022 31 Installation on wood 60 170 mm ETICS Installation of the anchor rods Drilled hole preparation ø14 mm Observe the anchoring depth and the minimum edge distance of 100 mm Drilled hole cleaning Lubricate threaded rod Screw threaded rod into the wood Installation of the Thermax following approval Z 21 8 1837 Milling open the thermal insulation Sealing of the expansion joint Installation of the...

Page 9: ...racket type I while doing so push the anchor rod through the bitumen band Position washer and nut and tighten them The bracket must be sealed all around again by means of a joint between ETICS surface and bracket Fischer multi adhesive and sealant Legend Wall bracket type I Bitumen band Sealing joint all around The sealing joints are maintenance joints that must be checked and maintained at regula...

Page 10: ...h the bracket Legend Bracket Cylinder head screw M8x16 Mounting clamp Plain washer Top board Slot nut 1 2 3 6 5 4 Installation instructions and Instructions for use Subject to technical modifications Date of Issue April 2022 39 Installation of the awning Observe the installation dimensions as shown below Wall installation Ceiling installation Rafter installation 222 250 288 264 288 264 190 Install...

Page 11: ...tric bush 6 by means of an Allen key 8 mm 7 Please note The position mark 9 of the eccentric bush must be within the indicated adjustment range 10 Otherwise the parallelism of the arm to the casing can be adjusted however the awning will still extend askew The arm should be parallel to the casing of the awning For facilitated adjustment the arm can be supported by hand 8 Check the adjustment of th...

Page 12: ...instructions for adjusting the end positions can be found in the enclosed documents of the motor manufacturer Legend End cap Front rail Motor head Adjustment screws for end positions Adjustment holes Allen key 4 mm 1 1 2 2 5 4 6 3 Installation instructions and Instructions for use Subject to technical modifications Date of Issue April 2022 47 Installation linked units Standard situation Attention ...

Page 13: ...as shown Then the second side of the slot nut is secured by the threaded pin Legend Sealing joint The junction at the coupling end caps must be sealed by means of a sealing joint 2 1 4 4 3 1 Installation instructions and Instructions for use Subject to technical modifications Date of Issue April 2022 51 Overview Linking Elements Screw together both awnings with the enclosed screws over the roller ...

Page 14: ...roper installation Never simultaneously activate the drives with an UPWARDS and a DOWNWARDS signal Keep a break of approx 0 5 seconds between the UPWARDS and the DOWNWARDS command is often neglected with Instabus EIB systems Radio interference suppression The drives are provided with a radio interference suppression according to the current VDE standards and EC Guidelines If the drives are operate...

Page 15: ...structions 3 1N 2 3 PE 2 M 1 4 1 L1 N PE Installation instructions and Instructions for use Subject to technical modifications Date of Issue April 2022 59 Wiring diagram for motors with ONYX NODE Drive system awning Legend Drive system awning Hirschmann connector Junction box Mains Button ONYX NODE Drive system Varioplus Legend Drive system Varioplus Junction box Mains Button ONYX NODE For more de...

Page 16: ...a Light temperature 2700 K warm white Colour rendering index of the LED strips 90 Control LED Somfy io ONYX dimmable Operating temperature outside temperature 20 C to 45 C IP rating IP44 Cable 10 m with open end piece The control of LED lighting is possible with Somfy io or ONYX The individual modules are described in the following 2 3 1 Installation instructions and Instructions for use Subject t...

Page 17: ...ens showing all available devices The overview displays ONYX LED as LED ONYX LED is connected with the hand held radio transmitter via Adaption to the system Then follow the instructions on the screen The configuration is continued as described in the instructions for use for ONYX CLICK Configuration of ONYX LED with ONYX CENTER Before you can use ONYX LED in combination with ONYX CENTER ONYX CENT...

Page 18: ...vice in accordance with the current country specific regulations for electronic scrap e g suitable collecting points Installation instructions and Instructions for use Subject to technical modifications Date of Issue April 2022 71 Replacing a folding arm with integrated LED lighting Control of the LED lighting with the control module Somfy Information about the commissioning and operation of the L...

Page 19: ...e 1 2 3 4 Installation instructions and Instructions for use Subject to technical modifications Date of Issue April 2022 75 Replacing a folding arm with integrated LED lighting Exchange procedure 2 Provide the electrical connection 24 V between folding arm and LED control unit again After the installation of the new folding arm the previously disconnected 24 V power supply line between the folding...

Page 20: ...to technical modifications Date of Issue April 2022 Removal and Disposal With removal or disposing of the awing the parts that are under prestress e g articulated arms counter draw systems must be completely released from tension and protected against unintentional drawing out before removal For this please contact a specialist enterprise Installation instructions and Instructions for use Subject ...

Page 21: ... serve for the light regulation as view protection anti glare blind and heat protection HELLA Front mounted Roller Shutter for more safety and protection against rain wind heat the cold noise incident light and nosey glances also available for subsequent installation HELLA Vertical awning With toggle catch mechanism for a lovely façade design with perfect heat and glare protection For questions wi...

Reviews: