background image

9600 Compressor Schematics (Low Voltage - Three Phase Cryopump Power) 

Figure 1-4: On-Board Splitter Box Schematic

DATE

APPROVED

REVISIONS

1

UM

11/22/95

REV

DESCRIPTION

A

INITIAL RELEASE PER DEO 10922

2

3

4

D

1
2
3
4
5
6
7
8

P18

A
B

BLK
RED

P30

1
2
3
4
5
6
7
8

J18

1
2
3
4
5
6
7
8

J21

1
2
3
4
5
6
7
8

P21

A
B
C
D
E
F

BLK

RED

WHT/RED

WHT/ORN

BRN
VIO

J27

D

G

H
J
K

A
B

GRA

YEL

G

R

N

/

Y

E

L

BLK

RED

J28

1
2
3
4
5
6
7

8

J22

1
2
3
4
5
6
7

8

P22

1
2

3
4
5
6

P19

C
D
E
F
G
H
J
K

WHT/RED

WHT/ORN

BRN
VIO
GRA
YEL

G

R

N

/

Y

E

L

1
2

3
4
5
6

J19

C

A

B

BLU

WHT/BLU

P31

1
2
3
4
5
6
7
8

J23

1
2
3
4

J24

1
2
3
4

P24

1
2
3
4
5
6
7
8

P23

C
D
E
F
G
H
J
K

WHT/ORN

WHT/RED

BRN
VIO

GRA

YEL

C

A
B
C
D
E
F
G
H
J
K

BLK

RED

WHT/RED

WHT/ORN
BRN

VIO

GRA

YEL

J29

1
2
3
4

J26

1
2
3
4

J25

1
2
3
4

P25

1
2
3
4

P26

B

8135199G001

1
2

J20

BLU
WHT/BLU

1
2

P20

CON2

A

B

P32

B

CTI-CRYOGENICS

HELIX TECHNOLOGY CORPORATION

DATE

BY

DRAWN

CHECKED

PROPRIETARY NOTICE

EXCEPT AS OTHERWISE AGREED
IN WRITING, THE INFORMATION
AND DESIGN DISCLOSED HEREIN

A

4

ORCAD V4.04

CAD FILENAME: /ORCAD/

8135220/220P001.SCH

ARE THE PROPERTY OF
CTI-CRYOGENICS AND MUST NOT
BE COPIED OR DISTRIBUTED

OUTSIDE CTI-CRYOGENICS
EXCEPT TO AUTHORIZED PERSONS
WITH A GENUINE NEED-TO-KNOW
WHO BY THE USE HEREOF ACKNOW-
LEDGE CTI-CRYOGENICS OWNER-
SHIP AND AGREE TO MAINTAIN
THIS INFORMATION AND DESIGN
IN STRICT CONFIDENCE.

NEXT ASSY

3

2

SIZE

ENG APPVL

ENG APPVL

QA APPVL

PROD

PRE-PROD

B

ENG APPVP

DWG NO

CAGE CODE

31949

1

8135220P001

SCHEMATIC, ON-BOARD

SPLITTER BOX

SHEET

OF

REV

1

1

A

A

Summary of Contents for Compressor 9600

Page 1: ...LOGY CORPORATION http www helixtechnology com ELIX H 2004 Helix Technology Corporation Pub No 8040426 Rev 101 2 10 04 ECO No 16163 Printed in USA 9600 Compressor Schematics Low Voltage Three Phase Cry...

Page 2: ......

Page 3: ...expressed written permission from Helix Technology Corporation is strictly prohibited Any correspondence regarding this document should be forwarded to Helix Technology Corporation Mansfield Corporat...

Page 4: ......

Page 5: ...rporation Pub No 8040426 Rev 101 2 10 04 ECO No 16163 v ELIX H Table of Contents Tables Figures Compressor Safety Schematics Introduction 1 1 Appendix A Customer Support Information Customer Support C...

Page 6: ......

Page 7: ...ables Table 1 1 Legend Basic Control Assembly 1 1 Table 1 2 Legend On Board Cryo Electrical Module P N 8135127G001 1 2 Table 1 3 Legend On Board Output Module P N 8135148G001 1 3 Table 1 4 Legend Cryo...

Page 8: ......

Page 9: ...8040426 Rev 101 2 10 04 ECO No 16163 ix Figures Figure 1 1 9600 Compressor Low Voltage Schematic 1 5 Figure 1 2 Autoset Voltage Control Schematic 1 6 Figure 1 3 Interface Cryo Torr Box Schematic 1 7...

Page 10: ......

Page 11: ...re all electrical power is OFF before proceeding with this procedure Disconnecting means the switch at the power entry module is set to the OFF position or the power cord shall be disconnected from th...

Page 12: ...orporation WARNING This is a general warning that describes various safety hazards or unsafe practices that could result in personal injury or death CAUTION Burn hazard Allow the Compressor pump to co...

Page 13: ...dentifier Description 1M Compressor Motor J15 Module Power Receptacle J1 P1 Autoset Power Connector J2 P2 Unload Solenoid Connector J3 P3 Oil Solenoid Connector J4 P4 J5 P5 J6 P6 Compressor Contactor...

Page 14: ...yo Electrical Module P N 8135127G001 Identifier Description JT1 PT3 T2 Cold Head Supply 3 phase JT2 PT4 T1 Cold Head Supply 3 phase JT3 Open JT4 Open JT5 PT5 T2 Cold Head Transformer Output JT6 PT6 T1...

Page 15: ...nector P31 Remote Jumper Table 1 4 Legend Cryo Torr Interface P N 8135904P001 Identifier Description J27 Coldhead 1 Output Receptacle J28 Coldhead 2 Output Receptacle J29 Coldhead 3 Output Receptacle...

Page 16: ...n J P18 On Board HV Input J P19 On Board Control Input J P20 Compressor Remote Connector J P21 On Board 1 HV Connector J P22 On Board 2 HV Connector J P23 On Board 3 HV Connector J P24 On Board 1 HV C...

Page 17: ...1 04 REMOTE EXCEPT AS OTHERWISE AGREED IN WRITING THE INFORMATION AND DESIGN DISCLOSED HEREIN ARE THE PROPERTY OF CTI CRYOGENICS AND MUST NOT BE COPIED OR DISTRIBUTED OUTSIDE CTI CRYOGENICS EXCEPT TO...

Page 18: ...12 94 GW 1 95 ENG APPVL DRAWN CHECKED ENG APPVL DRAWN CHECKED ENG APPVL EXCEPT AS OTHERWISE AGREED IN WRITING THE INFORMATION AND DESIGN DISCLOSED HEREIN ARE THE PROPERTY OF CTI CRYOGENICS AND MUST N...

Page 19: ...TERFACE CRYO TORR BOX DATE BY DATE BY ENG APPVL DRAWN CHECKED ENG APPVL DRAWN CHECKED ENG APPVL EXCEPT AS OTHERWISE AGREED IN WRITING THE INFORMATION AND DESIGN DISCLOSED HEREIN ARE THE PROPERTY OF CT...

Page 20: ...GRA YEL C A B C D E F G H J K BLK RED WHT RED WHT ORN BRN VIO GRA YEL J29 1 2 3 4 J26 1 2 3 4 J25 1 2 3 4 P25 1 2 3 4 P26 B 8135199G001 1 2 J20 BLU WHT BLU 1 2 P20 CON2 A B P32 B CTI CRYOGENICS HELIX...

Page 21: ...our 7 day per week Guaranteed Up Time Support GUTS dial 800 367 4887 Inside the United States of America 508 337 5599 Outside the United States of America Product Information Please have the following...

Page 22: ......

Reviews: